Engineered for higher-draw 120V residential circuits, this 30A single-pole breaker provides essential overload and short-circuit defense. The thermal-magnetic trip mechanism ensures consistent performance while maintaining a strict UL 489 listing. Installation is straightforward when servicing older Challenger Type C load centers. The plug-on mounting style also fits into Westinghouse and Eaton BR panels, acting as a seamless substitute for the BR130.
Challenger Type C Load Centers, Eaton Type BR Load Centers, Westinghouse Type BR Load Centers
Wire Gauge
14 AWG - 4 AWG (Cu/Al)
Max Wire
4 AWG
Min Wire
14 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed Thermal, Fixed Magnetic
Standards and features
Standards
UL 489
Approval
HACR, UL
Temp Rating
40C
Construction Features
HACR Rated
Product FAQs
7 answers
Can an Eaton BR130 be used to replace a Challenger C130?
Yes, Eaton BR series breakers, including the BR130, are UL approved direct replacements for Challenger Type C breakers in Challenger, Westinghouse, and Eaton BR load centers.
Is the Challenger C130 suitable for HVAC equipment?
Yes, this breaker is HACR rated, making it suitable for use with heating, air conditioning, and refrigeration equipment that requires a 30A circuit.
What are the terminal specifications for the C130?
The breaker is equipped with box lugs that accept 14 AWG to 4 AWG copper or aluminum conductors. Ensure proper torque is applied during installation as specified by the panel manufacturer.
Does the C130 breaker require a full-size panel space?
Yes, the C130 is a standard 1-inch wide plug-on breaker and requires one full 1-inch space on the panel bus bar.
What panels are UL listed to accept Challenger Type C breakers?
The C130 is compatible with Challenger Type C load centers, as well as Eaton Type BR and Westinghouse Type BR load centers.
How does the trip mechanism function on the C130?
The breaker utilizes a fixed thermal-magnetic trip unit. The thermal component provides long-time delay protection against sustained overloads, while the magnetic component offers instantaneous tripping during short circuit events.
Are there safety considerations when swapping out older Challenger breakers?
When replacing legacy Challenger breakers, verify that the panel label lists Type C or Type BR breakers as acceptable. Eaton BR breakers are the UL classified modern replacements for these legacy systems. Always de-energize the panel before servicing.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.