Skip to main content

Zinsco HRGF15 GFCI Molded Case Circuit Breaker

  • 15A
  • 1 Pole
  • Plug-On
Zinsco HRGF15
GFCI Molded Case Circuit Breaker
Brand Zinsco
SKU HRGF15
Select Item Condition
Earn 265 SuperPoints
  • 15A
  • 1 Pole
  • Plug-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Zinsco HRGF15 - 15A GFCI Molded Case Circuit Breaker

Re-Certified

$265.00 No Stock

Quantity

Description

Built for residential applications, the Zinsco HRGF15 delivers ground-fault protection for 15A, 120V circuits. It features a pigtail neutral to meet NEC requirements for wet and damp locations. This plug-on breaker installs into legacy Zinsco load centers without adapters. It serves as an exact replacement for original hardware and crosses to the UBIZ15 substitute. Rated at 10 kAIC, this thermal-magnetic unit provides essential long-time, instantaneous, and ground-fault protection.

Specifications

Key specifications
Brand Zinsco
Series HRGF
Amperage 15A
Poles 1
Mounting Style Plug-On
Voltage 120VAC
Phase 1
AIC Rating 10kA @ 120VAC
Fit and installation
Terminal Type Lugs
For Use With Zinsco Load Centers
Wire Gauge 14-2 AWG
Max Wire 2 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LIG
Trip Function Long-Time, Instantaneous, Ground Fault
Trip Adjustability Fixed
Standards and features
Special Classification GFCI
Accessories Pigtail Neutral
Standards UL 489
Approval UL
Temp Rating 40°C
Construction Features Ground Fault Protection

Product FAQs

5 answers
Which load centers accept the Zinsco HRGF15 circuit breaker?

The HRGF15 is a plug-in breaker designed specifically for legacy Zinsco load centers. It is also compatible with certain older Sylvania and GTE panels that were manufactured to accept Zinsco-style breakers.

How do I wire the pigtail neutral on the HRGF15?

The white pigtail wire attached to the breaker must be connected directly to the panel's neutral bus bar. The neutral wire from the branch circuit connects to the designated neutral terminal on the breaker itself to ensure proper ground fault detection.

Can the HRGF15 be used on a multi-wire branch circuit with a shared neutral?

No. Single-pole GFCI breakers require a dedicated neutral for the circuit they protect. The branch circuit neutral must connect directly to the breaker to accurately monitor for ground faults. Sharing a neutral will cause the breaker to trip immediately.

Are the trip settings on the HRGF15 adjustable?

No, the thermal-magnetic trip unit features fixed long-time, instantaneous, and ground fault trip settings.

Is the HRGF15 an exact replacement for older Zinsco GFCI breakers?

Yes, the HRGF15 is the direct replacement for legacy 15A, 1-pole Zinsco ground fault breakers. It maintains the original plug-in mounting style required to connect to Zinsco bus bars.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.