The CH220AFIT is a 2-pole, 20A branch/feeder arc fault circuit breaker from Eaton's CH series. Designed for residential applications, it provides essential protection against electrical fires caused by arcing faults in home wiring. This plug-on breaker installs into Eaton CH load centers and features a pigtail neutral connection. Rated at 10 kAIC for 120/240V systems, the unit utilizes thermal-magnetic trip technology with an independent trip mechanism. It is UL 1699 and UL 489 listed.
What load centers are compatible with the CH220AFIT circuit breaker?
The CH220AFIT is designed exclusively for use in Eaton CH-series load centers. It is not compatible with Eaton BR-series or other manufacturers' panels.
Does the CH220AFIT require a pigtail neutral connection?
Yes, this breaker features a pigtail neutral design. The attached coiled white wire must be connected directly to the panel's neutral bus bar for the arc fault circuitry to function properly.
Can the 2-pole CH220AFIT be used on shared neutral circuits?
Yes, 2-pole AFCI breakers like the CH220AFIT are commonly used to provide arc fault protection for multi-wire branch circuits (MWBC) that share a single neutral wire across two 120V legs.
What does the red diagnostic LED on the CH220AFIT indicate?
The red LED displays a blink code indicating the cause of the most recent trip, such as 1 blink for a series arc, 2 for a parallel arc, or 4 for overvoltage. This helps electricians troubleshoot the specific fault on the branch circuit.
Why is the red LED on my CH220AFIT staying solidly illuminated without tripping?
A constantly illuminated red LED is a known cosmetic firmware variation on some Eaton AFCI breakers. It is not a programmed fault code and does not indicate an unsafe condition or a loss of arc fault protection.
What is the difference between the CH220AF and the CH220AFIT?
The CH220AFIT is the updated version of the CH220AF. The IT designation indicates the inclusion of advanced diagnostic electronics, such as the LED trip indicator, to assist with troubleshooting arc faults.
Is the CH220AFIT rated for HVAC equipment?
Yes, Eaton CH molded case circuit breakers are HACR rated, making this 20A 2-pole breaker suitable for heating, air conditioning, and refrigeration applications that require arc fault protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 74 reviews.
5.0
Rated 5.0 out of 5 stars
Based on 74 reviews
5
Rated out of 5 stars
72
Total 5 star reviews: 72
4
Rated out of 5 stars
2
Total 4 star reviews: 2
3
Rated out of 5 stars
0
Total 3 star reviews: 0
2
Rated out of 5 stars
0
Total 2 star reviews: 0
1
Rated out of 5 stars
0
Total 1 star reviews: 0
Reviews Summary
Generated by AI from 100 most recent customer reviews
Last updated 8/5/25
Customers say these electrical breakers are readily available when hard to find elsewhere. Many reviews mention fast shipping and accurate order fulfillment. Common feedback includes competitive pricing and proper packaging. Reviews note the products fit correctly and match specifications. While most highlight quick delivery times, some mention occasional supply delays. The ordering process receives praise for its simplicity.
BREAKER ARRIVED QUICKLY. WELL PACKAGED FOR PROTECTION.
CS
Christine S.
Verified Buyer
Reviewing
Eaton / Cutler-Hammer CH2100-LONG - 100A 2 Pole Molded Case Circuit Breaker
I recommend this product
Rated 5 out of 5 stars
5/18/26
Got a great refurbished breaker - saved a $6500 Service Replacement
When our main breaker frizzed out, the option we were presented with was replacing the entire panel and service due to the type and part - no longer produced for replacement parts. It would be a $6500 replacement.
We'll likely have to do it at some point but, for now, the replacement breaker we were able to source from Superbreakers (with a $25 warranty) was $5900 less expensive. installation ran a few hundred dollars and the tech said the part looked to be in excellent condition and was prepped for install as he would have hoped.