Schneider ElectricJJA36250U43X
Quantity
New
Quantity
Schneider ElectricJJA36250U43X
| Brand | Schneider Electric |
|---|---|
| Part Number | JJA36250U44X |
| Series | JJA |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 100-250A |
|---|
| Terminal Type | Lugs |
|---|---|
| For Use With | I-Line Panelboards, I-Line Switchboards |
| Wire Gauge | 3/0 AWG-350 kcmil (Al/Cu) |
| Max Wire | 350 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSIG |
| Trip Function | Long-Time, Short-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Adjustable |
| Trip Unit Model | MicroLogic 6.2A |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Communication Module |
|---|---|
| Accessories | Micrologic 6.2 A Trip Unit (Ammeter) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, NOM-003-SCFI-2000, UL 489 |
| Approval | CCC, CE, CSA, IEC, NEMA, NOM, UL |
| Temp Rating | -25C to 70C |
| Construction Features | HACR Rated, Current Limiting, Visual Trip Indicator, True RMS Sensing, Ground Fault Protection |
This breaker is designed for use in Square D I-Line panelboards and switchboards. It features a plug-on connection for the line side and mechanical lugs for the load side.
The U44X suffix signifies that the breaker is equipped with a Micrologic 6.2 A electronic trip unit. This provides Long-Time, Short-Time, Instantaneous, and Ground Fault (LSIG) protection, along with an integrated ammeter.
Yes. Because this breaker includes ground fault protection, an external neutral current transformer is required when installed on a 3-phase, 4-wire system to accurately sense ground fault currents.
No. I-Line circuit breakers feature a specific plug-on jaw design for the line side bus and are not suitable for reverse feeding applications.
Yes, the electronic trip unit allows you to adjust the pickup and delay settings for long-time, short-time, and ground fault protection, as well as the instantaneous pickup, ensuring precise coordination with your electrical system.
Yes, the JJA36250U44X can serve as a modern upgrade for legacy Square D 250A I-Line breakers, such as the KC36250, offering advanced electronic trip functions and true RMS sensing.
The factory-installed mechanical lugs on the load side accept aluminum or copper conductors ranging from 3/0 AWG to 350 kcmil. The line side utilizes an I-Line plug-on connection.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.