Engineered for commercial and industrial applications, the Siemens CLD63B600 is a 600A, 3-pole molded case circuit breaker from the Sentron LD-frame family. It provides reliable thermal-magnetic protection with fixed thermal and adjustable magnetic trip settings. This unit mount MCCB installs into Siemens P4 and P5 panelboards, switchboards, and motor control centers. Rated for 150 kAIC at 480VAC, it features a current-limiting, fuseless design and is HACR rated for HVAC equipment.

Specifications

Key specifications
Brand Siemens
Part Number CLD63B600
Series CLD6
Amperage 600A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC, 500VDC
Phase 3
AIC Rating 200kA @ 240VAC, 150kA @ 480VAC, 100kA @ 600VAC, 50kA @ 500VDC
Fit and installation
Terminal Type Lugs
For Use With Siemens Sentron Panelboards (Type P4, P5), Switchboards, Motor Control Centers
Wire Gauge Requires TA2J6500 Lugs: (2) 3/0 AWG - 500 kcmil (Cu) or (2) 4/0 AWG - 500 kcmil (Al)
Max Wire 500 kcmil
Min Wire 3/0 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits, Rotary Handle
Accessories Lugs not included (Requires TA2J6500)
Standards CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval CSA, IEC, UL
Temp Rating 40C
Construction Features HACR Rated, Current Limiting, Reverse Feed, Non-Interchangeable Trip, Trip-Free Mechanism

Product FAQs

7 answers
Which Siemens panelboards are compatible with the CLD63B600 breaker?

This LD-frame breaker is designed for use in Siemens Sentron Type P4 and P5 panelboards, as well as compatible Siemens switchboards and motor control centers.

What are the wire size requirements for the CLD63B600?

When equipped with the required TA2J6500 lugs, the breaker accepts two 3/0 AWG to 500 kcmil copper conductors, or two 4/0 AWG to 500 kcmil aluminum conductors per phase.

Is this a plug-in or bolt-on breaker?

The CLD63B600 is a unit mount, bolt-on circuit breaker. It requires bolted connections to the bus and is not designed for plug-in load centers.

What does the 'C' in the CLD63B600 part number signify?

The 'C' designates it as the ultra-high interrupting capacity tier within the Sentron LD frame family, providing a 150kAIC rating at 480VAC and 100kAIC at 600VAC.

Can the trip settings on this 600A breaker be adjusted?

The thermal (long-time) trip is fixed at 600 amps, but the magnetic (instantaneous) trip is adjustable to allow for proper coordination with downstream devices and motor inrush currents.

Is the Siemens CLD63B600 a direct replacement for the ITE CLD63B600?

Yes. Siemens acquired ITE and continued manufacturing the Sentron series under the Siemens brand. An ITE-branded CLD63B600 shares the exact same physical dimensions and electrical characteristics as the current Siemens version.

Is this breaker suitable for DC voltage systems?

Yes, the CLD63B600 is rated for DC applications up to 500VDC, where it provides an interrupting capacity of 50kA.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.