Eaton / Cutler-HammerPDG33M0400TFAJ
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG3 |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Frame 3 Panelboards, Switchboards |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Handle Lock, Motor Operator, Terminal Shields, Lug Kits |
|---|---|
| Accessories | No Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CCC, CE, CSA, IEC, UL, RoHS |
| Temp Rating | -20C to 70C |
| Construction Features | HACR Rated, Current Limiting, RoHS Compliant, CCC Marked |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG3 |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Frame 3 Panelboards, Switchboards |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Handle Lock, Motor Operator, Terminal Shields, Lug Kits |
|---|---|
| Accessories | No Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CCC, CE, CSA, IEC, UL, RoHS |
| Temp Rating | -20C to 70C |
| Construction Features | HACR Rated, Current Limiting, RoHS Compliant, CCC Marked |
Eaton / Cutler-HammerPDG33M0400TFAJ
Eaton / Cutler-HammerPDG33M0350TFAJ
Eaton / Cutler-HammerPDG33M0500TFAJ
Eaton / Cutler-HammerPDG33M0300TFAJ
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG3 |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Frame 3 Panelboards, Switchboards |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Handle Lock, Motor Operator, Terminal Shields, Lug Kits |
|---|---|
| Accessories | No Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CCC, CE, CSA, IEC, UL, RoHS |
| Temp Rating | -20C to 70C |
| Construction Features | HACR Rated, Current Limiting, RoHS Compliant, CCC Marked |
This Power Defense Frame 3 breaker is specifically designed for Eaton Power Defense panelboards and switchboards. While it replaces the legacy Series G LGH3400FAG electrically, you must verify your existing panelboard mounting hardware and bus connections before upgrading older enclosures.
This Frame 3 Power Defense breaker serves as a direct replacement for the legacy Series G LGH3400FAG molded case circuit breaker.
This breaker features a thermal-magnetic trip unit. The thermal element for Long-Time overload protection is fixed at 400A, while the magnetic element for Instantaneous short-circuit protection is adjustable via a dial on the face of the trip unit.
No, this breaker is equipped with a standard LI (Long-Time, Instantaneous) thermal-magnetic trip unit. Applications requiring ground fault protection must use a breaker equipped with an electronic trip unit featuring LSG or LSIG functions.
In Eaton's Power Defense nomenclature, "T" designates a thermal-magnetic trip unit, "F" indicates a fixed thermal setting, and "A" specifies an adjustable magnetic pickup.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.