Skip to main content

Siemens / ITE HE63B090 Molded Case Circuit Breaker

  • 90A
  • 3 Pole
  • Bolt-On
Siemens / ITE HE63B090
Molded Case Circuit Breaker
Brand Siemens / ITE
SKU HE63B090
Select Item Condition
Earn 270 SuperPoints
  • 90A
  • 3 Pole
  • Bolt-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Siemens / ITE HE63B090 - 90A 3 Pole Molded Case Circuit Breaker

Siemens / ITE HE63B090 - 90A 3 Pole Molded Case Circuit Breaker

Re-Certified

$270.00 No Stock

Quantity

Description

Part of the legacy E-frame series, this 90A molded case circuit breaker provides reliable thermal-magnetic protection for commercial distribution systems. It fits seamlessly into older Siemens P1, P2, and P3 panelboards. As an exact replacement for aging infrastructure, it installs into existing bolt-on configurations. This unit is superseded by the HHED63B090 for newer setups. Rated for 30kAIC at 480VAC, the 3-pole unit features fixed LI trip functions and includes load side lugs.

Specifications

Key specifications
Brand Siemens / ITE
Series HE
Amperage 90A
Poles 3
Mounting Style Bolt-On
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 65kA @ 240VAC, 30kA @ 480VAC, 18kA @ 600VAC
Fit and installation
Frame Type HE6
Terminal Type Lugs
For Use With Siemens P1, P2, P3 Panelboards, Switchboards
Wire Gauge 10-1/0 AWG (Cu/Al)
Max Wire 1/0 AWG
Min Wire 10 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release
Accessories Load Side Lugs
Standards UL 489, CSA C22.2 No. 5.1, NEMA AB-1
Approval CSA, UL
Temp Rating 40C
Construction Features HACR Rated, High Interrupting Capacity, Non-Interchangeable Trip

Product FAQs

7 answers
Can I install the HE63B090 in a standard residential load center?

No, this is a legacy E-frame molded case circuit breaker designed for commercial and industrial distribution. It is compatible with Siemens P1, P2, and P3 panelboards and switchboards, and will not fit into standard residential plug-on load centers.

Does this breaker require a specific mounting hardware kit for panelboard installation?

Yes, installing an E-frame breaker like the HE63B090 into Siemens panelboards requires a dedicated breaker mounting strap or connector kit depending on your specific panelboard model. The breaker does not mount directly to the bus without the appropriate hardware kit.

Is the HE63B090 interchangeable with older ITE branded breakers?

Yes. Siemens acquired ITE, and the current Siemens HE63B090 serves as a direct, exact replacement for the original ITE-branded HE63B090 breakers. It maintains the same physical footprint, HE6 frame specifications, and bolt-on configuration.

What does the "LI" trip function code mean on this breaker?

The "LI" designation indicates that the breaker provides Long-Time (thermal) and Instantaneous (magnetic) trip functions. Both the thermal overload and magnetic short-circuit protection settings are fixed on the HE63B090 and cannot be adjusted in the field.

Are the lugs included with the HE63B090 rated for aluminum wiring?

Yes, the factory-installed lugs are dual-rated for both copper and aluminum conductors ranging from 10 AWG to 1/0 AWG. When terminating aluminum wire, electricians should apply a listed joint compound (oxide inhibitor) to prevent oxidation and ensure a secure connection.

Can I substitute the HE63B090 with an ED-frame breaker like the ED43B090 or ED63B090?

While the HE, ED, HED, and HHED series share the same physical E-frame dimensions and mounting hardware, they have different short-circuit interrupting capacities. The HE63B090 is rated for 30kAIC at 480V. You must verify the available fault current of your system before substituting one frame type for another to ensure code compliance.

What safety procedures are required when replacing a bolt-on breaker like the HE63B090?

Because it is a bolt-on breaker, it connects directly to the live busbars. You must completely de-energize and lock out the panelboard or switchboard before removing the deadfront cover or unbolting the existing breaker to prevent severe arc flash and shock hazards.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.