Engineered for commercial power distribution, the ABB XT2NU3125FYD000XXX is a 3-pole, 125A molded case circuit breaker from the SACE Tmax XT family. It provides reliable LSI protection via an advanced Ekip DIP electronic trip unit. This unit mount MCCB integrates with ABB ReliaGear neXT panelboards and SB switchboards. It also serves as a direct replacement for legacy GE Spectra SEHA36AT0125 and ABB Tmax T3N125TW breakers. Rated 25kAIC at 480VAC, it features adjustable trip settings.
ABB ReliaGear neXT Panelboards, ReliaGear SB Switchboards
Wire Gauge
10 AWG - 2/0 AWG (Cu/Al)
Max Wire
2/0 AWG
Min Wire
10 AWG
Protection and operation
Trip Technology
Electronic Trip
Trip Function Code
LSI
Trip Function
Long-Time, Short-Time, Instantaneous
Trip Adjustability
Adjustable
Standards and features
Available Options
Shunt Trip, Auxiliary Switch, Undervoltage Release, Motor Operator, Padlock Attachment, Terminal Lugs, DIN Rail Adapter
Accessories
Lugs Not Included
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CE, CSA, cULus, IEC, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Double Insulated, Reverse Feed
Product FAQs
8 answers
Which panelboards are compatible with the XT2NU3125FYD000XXX circuit breaker?
This breaker is designed for integration with ABB ReliaGear neXT Panelboards and ReliaGear SB Switchboards.
What wire sizes are accepted by the lugs on this XT2 breaker?
The factory installed lugs accept wire gauges from 10 AWG to 2/0 AWG and are rated for both copper and aluminum conductors.
What does the LSI designation mean on this electronic trip unit?
LSI indicates that the breaker features adjustable Long-Time, Short-Time, and Instantaneous trip functions. This allows for precise selective coordination and customized protection settings for your specific electrical system.
Can this ABB XT2 breaker be used in DC applications?
Yes, it is rated for DC systems, providing an interrupting capacity of up to 35kA at 500VDC.
How is the XT2NU3125FYD000XXX mounted?
This is a unit mount circuit breaker, meaning it is designed to be bolted or fixed directly to the panel or base rather than using a plug-in or drawout configuration.
What does the N in the XT2N frame designation indicate?
The N signifies ABB's Normal interrupting capacity tier for the XT2 frame, which provides a 25kA interrupting rating at 480VAC and 18kA at 600VAC.
Can this breaker replace legacy GE Spectra or older ABB Tmax models?
Yes, the XT2NU3125FYD000XXX serves as a direct replacement for legacy GE Spectra SEHA36AT0125 and older ABB Tmax T3N125TW circuit breakers.
Does this breaker use traditional thermal magnetic protection?
No, this specific model uses an electronic trip unit rather than traditional thermal magnetic elements. The electronic trip unit provides highly precise and adjustable protection against overloads and short circuits.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.