Built for circuit protection, the General Electric SKHH36AT1000 is a 3-pole molded case circuit breaker rated 1000A and 600VAC. Its interrupting rating is 50kA at 480VAC. This Spectra RMS breaker belongs to the SKHH series and uses an SK frame with bolt-on mounting and terminal connections. The adjustable electronic trip provides long-time, short-time and instantaneous trip functions. It has standard protection, 3-phase configuration and UL approval.
How should I use the 1000A rating when selecting the General Electric SKHH36AT1000?
The 1000A rated current is a starting point for load and conductor sizing. Evaluate it together with the adjustable trip settings and applicable circuit-sizing requirements rather than treating it as a trip-setting value.
How does the 600VAC rating guide circuit selection?
The 600VAC rating sets the breaker’s rated AC voltage limit. Select it for a circuit within that voltage rating, and evaluate interrupting capacity separately at the circuit’s operating voltage.
What does the 50kA interrupting rating at 480VAC mean for installation?
At 480VAC, the breaker has a 50kA interrupting rating. The available fault current at the installation point must not exceed that rating.
Why do the three poles matter for a three-phase circuit?
The three poles provide a breaker pole for each phase conductor of a three-phase circuit. Account for all three phase connections when planning conductor routing and termination.
What does bolt-on mounting and terminal connection mean for installation?
Both mounting and terminal connections use bolted joints. Installation requires securing the breaker mechanically and tightening the electrical connections using the applicable torque requirements.
What is the benefit of an adjustable electronic trip?
An electronic trip evaluates current electronically, while trip adjustability allows the protection response to be set for the application. Choose settings through a protection-coordination review that accounts for load behavior and conductor protection.
How does long-time protection handle overloads?
Long-time protection responds to sustained overcurrent with a delayed trip rather than an immediate response to every brief current rise. It helps protect against prolonged overloads while accommodating normal load behavior.
Why is short-time protection useful for coordination?
Short-time protection applies a brief delay to its overcurrent response. That delay can give downstream protection time to clear a fault first, so evaluate this function when coordinating circuit protection.
What does the instantaneous trip function do?
Instantaneous protection trips without intentional delay when current reaches its operating threshold. Consider normal inrush and fault-clearing needs when evaluating this function for the circuit.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.