Skip to main content
Expedited shipping available at checkout

Siemens Q1530NC 15/30A Tandem Miniature Circuit Breaker

  • 15/30A
  • 2 Pole
  • Plug-On
Siemens Q1530NC
15/30A Tandem Miniature Circuit Breaker
Brand Siemens
SKU Q1530NC
Select Item Condition
Earn 46 SuperPoints
  • 15/30A
  • 2 Pole
  • Plug-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Siemens Q1530NC - 15/30A Tandem Miniature Circuit Breaker

New

$46.40 In Stock

Quantity

Similar Items

Description

Delivering one 15A and one 30A circuit within a standard one-inch footprint, the Siemens Q1530NC tandem breaker maximizes capacity in crowded residential enclosures. This non-CTL plug-on breaker lacks a rejection clip, allowing it to mount into older pre-1968 ITE, Gould, and Siemens load centers. It also serves as an exact replacement for the discontinued MP1530N. Rated at 10 kAIC, it features reliable thermal-magnetic protection and is HACR rated for HVAC equipment.

Specifications

Key specifications
Brand Siemens
Series QT
Amperage 15/30A
Poles 2
Mounting Style Plug-On
Voltage 120/240VAC
Phase 1
AIC Rating 10kA @ 120/240VAC
Fit and installation
Frame Type Q
Terminal Type Lugs
For Use With Siemens Load Centers (Non-CTL), Older ITE/Gould Panels (Pre-1968)
Wire Gauge 15A Pole: 14-6 AWG (Cu), 12-6 AWG (Al); 30A Pole: 14-6 AWG (Cu), 12-6 AWG (Al)
Max Wire 6 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed
Standards and features
Special Classification Tandem
Available Options Padlock Attachment, Handle Tie
Standards HACR, SWD (15A Pole), UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features Space Saver, HACR Rated, Insta-Wire, Non-CTL

Product FAQs

6 answers
What does the NC suffix indicate on the Q1530NC breaker?

The NC stands for Non-Circuit Total Limiting (Non-CTL). This indicates the breaker does not have a rejection clip, allowing it to be installed in older panels that do not restrict the placement of tandem breakers.

Which load centers accept the Q1530NC tandem breaker?

This Non-CTL breaker is compatible with legacy Siemens, ITE, and Gould load centers manufactured before 1968 that lack CTL rejection features. It is not compatible with modern CTL-compliant panels.

How much panel space does the Q1530NC require?

As a tandem breaker, it provides two independent circuits within a single 1-inch pole space, allowing you to maximize capacity in older, space-constrained load centers.

Do the two circuits on this tandem breaker share a common trip?

No. The 15A and 30A circuits operate independently. An overload or short circuit on one circuit will not cause the other circuit to trip.

Is it safe to install a Non-CTL breaker in a modern panel?

No. Non-CTL breakers are strictly for replacement use in older panels. Installing them in modern panels bypasses safety rejection features designed to prevent exceeding the maximum circuit capacity of the load center.

Can this breaker replace older ITE or Gould tandem breakers?

Yes, the Siemens Q1530NC is the direct manufacturer replacement for legacy Non-CTL tandem breakers used in pre-1968 ITE and Gould electrical panels.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.