Eaton / Cutler-Hammer HMCP100K3C Motor Circuit Protector

  • 100A
  • 3 Pole
  • Unit Mount
Eaton / Cutler-Hammer HMCP100K3C
Motor Circuit Protector
Brand Eaton / Cutler-Hammer
SKU HMCP100K3C
Select Item Condition
Earn 660 SuperPoints
  • 100A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Eaton HMCP100K3C 3 Pole Circuit Breaker

Eaton / Cutler-Hammer HMCP100K3C - 100A 3 Pole Motor Circuit Protector

New

$660.53 In Stock

Quantity

Description

Built for motor circuit protection, the Eaton HMCP100K3C motor circuit protector uses magnetic-only tripping to respond to short circuits. It is rated for 100A at 600VAC and 250VDC. This HMCP series device has three poles and is rated for three-phase circuits. Its trip function is instantaneous only. Magnetic tripping provides short-circuit protection rather than thermal overload protection.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Part Number HMCP100K3C
Series HMCP
Amperage 100A
Poles 3
Mounting Style Unit Mount
Voltage 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 65kA @ 480VAC
Fit and installation
Terminal Type Lugs
Wire Gauge 14-1/0 AWG
Max Wire 1/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Magnetic Only
Trip Function Code I
Trip Function Instantaneous Only
Trip Adjustability Adjustable Magnetic
Standards and features
Available Options Alarm Switch, Auxiliary Switch, Shunt Trip, Undervoltage Release
Standards CSA C22.2 No. 5.1, IEC 60947-2, UL 489
Approval CSA, UL
Temp Rating 40C

Product FAQs

4 answers
Does the Eaton HMCP100K3C provide motor overload protection?

Its instantaneous, magnetic-only trip responds to high fault current rather than sustained motor overloads. Use separate motor overload protection as part of the motor circuit design.

How should I use the 100A current rating when selecting this motor circuit protector?

The 100A rated current is a selection point for the motor circuit's current requirements. Coordinate this rating with the circuit design and motor overload protection, rather than treating it as a thermal overload setting.

Can this motor circuit protector be used on AC or DC circuits?

It carries ratings of 600VAC and 250VDC. Select according to the circuit's supply type and keep its voltage within the applicable AC or DC rating.

How do the three poles relate to a three-phase motor circuit?

The three-pole arrangement provides a pole for each phase conductor in a three-phase motor circuit. Use this configuration when the circuit requires protection across all three phases.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

4.9
Rated 4.9 out of 5 stars
Based on 23 reviews
Rating
Ratings
23 reviews
  • JG
    Jay G.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HMCP030H1C - 30A 3 Pole Motor Circuit Protector
    I recommend this product
    Rated 5 out of 5 stars
    9/15/26
    Perfect fit

    Customer up and running

  • JG
    Jay G.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HMCP050K2 - 50A 3 Pole Motor Circuit Protector
    I recommend this product
    Rated 5 out of 5 stars
    9/15/26
    Eaton circuit breaker

    This replaced an old Cutler Hammer and it was a perfect fit

  • JW
    Joe W.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HMCP100R3 - 100A 3 Pole Motor Circuit Protector
    I recommend this product
    Rated 5 out of 5 stars
    8/28/26
    Best price around.

    Bought as a direct replacement.

    Item was very well packed to prevent damage during transit.

    It is working as it should.

  • RM
    Ryan M.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HMCP015E0C - 15A 3 Pole Motor Circuit Protector
    I recommend this product
    Rated 5 out of 5 stars
    7/1/26
    Great price and prompt delivery

    Very satisfied, will be a return customer.

  • CH
    curtis h.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HMCP150T4C - 150A 3 Pole Motor Circuit Protector
    I recommend this product
    Rated 5 out of 5 stars
    5/1/26
    150AMP CUTLER HAMMER/ EATON BREAKER

    Brand new in the box. They go the extra mile in shipping and packaging to made sure we receive in the best condition. Great price and James takes great care of us.