Engineered for modern safety codes, the CHFP120DF delivers 20A dual-function AFCI/GFCI protection. Its plug-on neutral connection removes the pigtail wire for a cleaner panel installation. This single-pole unit is designed exclusively for Eaton CH plug-on neutral load centers. It serves as a direct upgrade for previous iterations like the CHFPAFGF120. With a 10 kAIC rating at 120V, it includes a visual LED trip indicator and self-testing functionality to ensure continuous reliability.
Can I install the CHFP120DF in an older Eaton CH load center without a plug-on neutral bus?
No. The CHFP120DF requires an Eaton CH plug-on neutral (PON) load center. It does not have a pigtail wire and relies entirely on the integrated neutral clip to connect directly to the panel bus.
Which Eaton breaker should I use if my CH panel requires a pigtail neutral?
For older Eaton CH panels that do not accept plug-on neutral breakers, you will need catalog number CHFN120DF, which features a factory installed neutral pigtail wire.
Does this replace previous generations of CH dual function breakers?
Yes, the CHFP120DF is the current generation and acts as a direct replacement for older Eaton CH plug-on neutral dual function models, such as the CHFAFGF120PN and CHFPAFGF120.
What does the DF suffix indicate on this CH series breaker?
The DF suffix stands for Dual Function. It means the breaker simultaneously provides combination type arc fault circuit interrupter (AFCI) protection and Class A ground fault circuit interrupter (GFCI) protection.
What type of ground fault protection is included in the CHFP120DF?
This dual function breaker provides Class A ground fault protection, which is engineered to trip at 5mA of leakage current to ensure personnel safety against electrical shock.
How do you retrieve trip codes on this breaker?
When the breaker is turned back on after a fault, the red diagnostic LED on the face of the breaker will blink a specific 1 to 6 blink sequence indicating the exact cause of the trip, such as an overvoltage, series arc, or ground fault.
Does a solidly lit red LED indicate a malfunction?
No. Eaton confirms that a constantly illuminated red LED on an untripped CH dual function breaker is a known cosmetic behavior. It does not compromise the breaker's AFCI or GFCI protection capabilities and does not require replacement.
Why might the breaker experience a delayed trip when tested with a plug-in GFCI tester?
Eaton CH advanced dual function breakers are designed to ride through harmless transient currents on the equipment grounding conductor for up to 2.7 seconds. This intentional delay helps minimize nuisance tripping from devices like variable frequency drives and motor controllers.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 74 reviews.
5.0
Rated 5.0 out of 5 stars
Based on 74 reviews
5
Rated out of 5 stars
72
Total 5 star reviews: 72
4
Rated out of 5 stars
2
Total 4 star reviews: 2
3
Rated out of 5 stars
0
Total 3 star reviews: 0
2
Rated out of 5 stars
0
Total 2 star reviews: 0
1
Rated out of 5 stars
0
Total 1 star reviews: 0
Reviews Summary
Generated by AI from 100 most recent customer reviews
Last updated 8/5/25
Customers say these electrical breakers are readily available when hard to find elsewhere. Many reviews mention fast shipping and accurate order fulfillment. Common feedback includes competitive pricing and proper packaging. Reviews note the products fit correctly and match specifications. While most highlight quick delivery times, some mention occasional supply delays. The ordering process receives praise for its simplicity.
BREAKER ARRIVED QUICKLY. WELL PACKAGED FOR PROTECTION.
CS
Christine S.
Verified Buyer
Reviewing
Eaton / Cutler-Hammer CH2100-LONG - 100A 2 Pole Molded Case Circuit Breaker
I recommend this product
Rated 5 out of 5 stars
5/18/26
Got a great refurbished breaker - saved a $6500 Service Replacement
When our main breaker frizzed out, the option we were presented with was replacing the entire panel and service due to the type and part - no longer produced for replacement parts. It would be a $6500 replacement.
We'll likely have to do it at some point but, for now, the replacement breaker we were able to source from Superbreakers (with a $25 warranty) was $5900 less expensive. installation ran a few hundred dollars and the tech said the part looked to be in excellent condition and was prepped for install as he would have hoped.