Engineered as a drop-in solution for older systems, the Eaton C240 is a 40A, two-pole miniature circuit breaker. It provides reliable thermal-magnetic protection for residential and commercial 120/240V applications. This unit installs into Challenger Type C, Eaton BR, and Westinghouse BR load centers. As a verified cross-reference for the BR240 and UBITB240, it offers an exact fit for legacy enclosures. Rated for 10 kAIC, it features a common trip mechanism and HACR certification.

Specifications

Key specifications
Brand Eaton / Challenger
Part Number C240-R
Series Type C
Amperage 40A
Poles 2
Mounting Style Plug-On
Voltage 120/240VAC
Phase 1
AIC Rating 10kA @ 120/240VAC
Fit and installation
Terminal Type Box Lugs
For Use With Challenger Type C Load Centers, Eaton Type BR Load Centers, Westinghouse Type BR Load Centers
Wire Gauge #14-4 AWG (Cu/Al)
Max Wire 4 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed
Standards and features
Available Options Padlock Attachment
Standards UL 489
Approval CSA, HACR, UL
Temp Rating -25C to 70C
Construction Features Common Trip, HACR Rated

Product FAQs

8 answers
Can I install the Challenger C240 in an Eaton BR load center?

Yes. Eaton acquired Challenger, and modern Eaton BR load centers are UL listed to accept Challenger Type C breakers. Always verify that your specific panel label lists Type C breakers as an approved type before installation.

What is the modern replacement for the Challenger C240?

The Eaton BR240 is the direct, UL approved replacement for the Challenger C240. Eaton discontinued the Challenger brand and integrated the Type C line into their BR series.

Do I need a hold-down kit if I use this breaker as a main disconnect?

Yes. When using a plug-on breaker like the C240 in a back-fed main application, the National Electrical Code requires a mechanical hold-down retainer kit to secure it to the load center.

Is the Challenger C240 HACR rated?

Yes, this breaker is HACR certified, meaning it is approved for use with heating, air conditioning, and refrigeration equipment that requires this specific safety rating.

Will this breaker fit in a Square D or Siemens panel?

No. The C240 is only designed for Challenger Type C, Eaton BR, and Westinghouse BR load centers. It is not UL classified for use in Square D, Siemens, or GE panels.

What does the LI trip function mean on this breaker?

The LI designation stands for Long-Time and Instantaneous trip functions. The long-time function protects against sustained overloads, while the instantaneous function trips the breaker immediately during a severe short circuit.

How does the thermal magnetic trip technology work in this breaker?

The thermal component responds to heat buildup from prolonged overloads, while the magnetic component reacts instantly to short circuits. This dual mechanism ensures comprehensive protection for your electrical system.

Can this 2-pole breaker be used to supply two separate 120V circuits?

Yes, a 2-pole breaker can supply a multi-wire branch circuit sharing a neutral, providing two independent 120V circuits. However, both circuits will trip simultaneously if a fault occurs on either leg due to the common internal trip mechanism.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.