Utilizing advanced current-limiting technology, this 400A L-Frame breaker significantly reduces let-through energy during severe fault conditions. It boasts a massive 200kAIC rating at 240V and 100kAIC at 480V, making it ideal for high-capacity industrial networks. The unit integrates into Eaton Pow-R-Line 4 panelboards and motor control centers. Equipped with adjustable magnetic trip settings and a trip-free mechanism, it ensures precise coordination and reliable circuit isolation.
Current Limiting, HACR Rated, High Interrupting Capacity, Trip-Free Mechanism, Visual Trip Indicator
Product FAQs
8 answers
What is the difference between the Eaton LD3400, HLD3400, and LDC3400?
These breakers share the same physical L-frame footprint but have different interrupting capacities. The LD3400 is the standard tier, the HLD3400 is high-interrupting, and the LDC3400 is the ultra-high current limiting version rated for 200kA at 240V and 100kA at 480V.
What equipment is the LDC3400 designed to be installed in?
This Series C L-frame breaker is compatible with Eaton Pow-R-Line 4 panelboards, switchboards, and motor control centers.
Can the LDC3400 replace an older Westinghouse L-frame breaker?
Yes, Eaton Cutler-Hammer Series C breakers are backwards compatible. The LDC3400 will physically fit in the same mounting space as older Westinghouse or Cutler-Hammer LD, HLD, and LDC breakers with the same pole and amperage configuration.
What does the 'C' in the LDC3400 catalog number indicate?
The 'C' designates this as a current limiting circuit breaker. It is designed to significantly reduce let-through energy during severe fault conditions compared to standard LD or HLD frames.
What lugs are used with the LDC3400, and what wire sizes do they accept?
This breaker typically uses 3TA401LDK line and load lugs, which accept either aluminum or copper wire ranging from 4/0 AWG to 600 kcmil.
How is the LDC3400 mounted in an enclosure?
It features a unit mount configuration, meaning it bolts securely to the backpan of the panelboard or switchboard rather than plugging directly onto the bus bars.
Are the trip settings on the LDC3400 adjustable?
The thermal protection (Long-Time) is fixed at 400 amps, but the magnetic protection (Instantaneous) is adjustable, allowing electricians to coordinate the trip response with other devices in the system.
Can the LDC3400 be used in DC applications?
Yes, in addition to its 600VAC rating, this breaker is rated for 250VDC with an interrupting capacity of 22kA.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.