Eaton / Cutler-Hammer CHND312T32W Molded Case Circuit Breaker

  • 1200A
  • 3 Pole
  • Panel Mount
Eaton / Cutler-Hammer CHND312T32W
Molded Case Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU CHND312T32W
Select Item Condition
Earn 11882 SuperPoints
  • 1200A
  • 3 Pole
  • Panel Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Eaton / Cutler-Hammer CHND312T32W - 1200A 3 Pole Molded Case Circuit Breaker

New

$11,882.75 Check Stock

Quantity

Description

Delivering precise LSI protection, the 1200A, 3-pole CHND312T32W molded case circuit breaker meets the demands of heavy-duty commercial applications. It utilizes a microprocessor-based Digitrip 310 electronic trip unit. This N-Frame breaker is engineered for panel mount installation in Eaton Series C panelboards. Supplied without terminals, it serves as a drop-in replacement for older units and is officially replaced by the PDF53M1200E2NN. It is 100% rated for continuous use.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Series CHND
Amperage 1200A
Poles 3
Mounting Style Panel Mount
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC
Electrical ratings
Amperage Range 600-1200A
Fit and installation
Frame Type NG
Terminal Type Lugs
For Use With Eaton Series C Panelboards, Switchboards, Motor Control Centers
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LSI
Trip Function Long-Time, Short-Time, Instantaneous
Trip Adjustability Adjustable
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits, Rating Plugs, Padlock Attachment
Accessories Without Terminals
Standards CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489
Approval CSA, HACR, UL
Temp Rating 40C
Construction Features 100% Rated, HACR Rated, Reverse Feed, Non-Interchangeable Trip

Product FAQs

8 answers
Is the Eaton CHND312T32W rated for 100 percent continuous operation?

Yes, the C prefix in the CHND frame designation indicates this breaker is 100 percent rated. It can carry its full 1200A continuous current rating when installed in a properly sized and ventilated enclosure. The 1200A version requires specific enclosure ventilation, conductor extensions, and terminal barriers, and 90 degree C wire must be applied at the 75 degree C ampacity.

Does the CHND312T32W require a rating plug to operate?

Yes, this breaker features a Digitrip 310 electronic trip unit which requires an interchangeable N-frame rating plug to set the continuous current rating. The breaker will not function properly without the correct rating plug installed.

What type of trip unit is installed in the CHND312T32W?

It is equipped with a Digitrip RMS 310 solid-state electronic trip unit. The T32 designation indicates it provides LSI (Long-Time, Short-Time, and Instantaneous) protection functions, allowing for precise coordination in your electrical system.

What settings are adjustable on the CHND312T32W trip unit?

The Digitrip 310 LSI trip unit allows you to adjust the Long Delay pickup via the rating plug. It also features an adjustable Short Delay pickup with fixed or adjustable delay time, and an adjustable Instantaneous pickup configured by setting the short delay time to instantaneous.

Can the CHND312T32W be used in DC power systems?

No, the Digitrip 310 electronic trip unit installed in this breaker relies on true RMS current sensing and is designed for AC applications only.

How is the CHND312T32W mounted in a panelboard or switchboard?

This is a bolt-on, panel-mount N-frame circuit breaker designed for use in Eaton Series C panelboards, switchboards, and motor control centers.

Does the CHND312T32W provide ground fault protection?

No, the LSI trip unit provides Long-Time, Short-Time, and Instantaneous protection. It does not include integral ground fault protection. If ground fault protection is required, a different trip unit configuration, such as LSIG, would be necessary.

What is the ambient operating temperature range for the CHND312T32W?

The Digitrip 310 trip unit is calibrated to be insensitive to ambient temperatures between -20 degrees C and +55 degrees C. However, for ambient conditions above 40 degrees C, derating of the circuit breaker should be considered to avoid exceeding safe terminal temperatures. The trip unit also contains thermal protective circuitry that initiates a trip if the internal printed circuit board reaches approximately 90 degrees C.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.