Part of the CSH series, the Eaton CSH2175N is a 175-amp, two-pole main circuit breaker designed for residential and commercial applications. It delivers reliable thermal-magnetic trip protection for main service entrances. This bolt-on unit installs into Eaton CH load centers and Type ECB unit enclosures, serving as a direct replacement for the legacy CSR2175N. Rated at 35 kAIC at 120/240VAC, it accepts #2 AWG to 300 kcmil copper or aluminum wire for flexible installation.
What load centers and enclosures are compatible with the Eaton CSH2175N?
The CSH2175N is designed for use as a main breaker in Eaton CH series load centers and Type ECB unit enclosures.
What is the difference between the Eaton CSR2175N and the CSH2175N?
Both are 175A, 2-pole main breakers with the same physical dimensions, but they have different interrupting ratings. The CSR2175N is rated at 25kAIC, while the CSH2175N offers a higher 35kAIC rating for systems requiring greater fault current protection.
How is the CSH2175N main breaker installed in a load center?
This breaker mounts directly to the interior bus of the load center. It is secured over the studs using 1/4-20 nuts, which must be torqued to the manufacturer's specifications. Always ensure power is disconnected before installation.
What wire sizes and materials are accepted by the lugs on the CSH2175N?
The terminal lugs are rated for both copper and aluminum conductors, accepting wire gauges from 2 AWG up to 300 kcmil. Ensure proper torque is applied to the lugs during installation to maintain a secure connection.
When should I use the CSH2175N instead of a standard main breaker?
The CSH2175N is required when the electrical system's available fault current exceeds 25kAIC. Its 35kAIC rating at 120/240VAC provides the necessary interrupting capacity for higher fault current environments, whereas standard CSR breakers are only rated for 25kAIC.
What type of trip mechanism does the CSH2175N use?
It utilizes a fixed thermal-magnetic trip unit. The thermal element provides long-time protection against sustained overloads, while the magnetic element delivers instantaneous protection against short circuits.
Do I need a terminal insulator kit when installing the CSH2175N?
Yes, terminal insulators must be installed on the service entry cable and line-side lugs of the main breaker. Eaton typically includes these kits with 225A and smaller main breaker load centers from the factory.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.