Engineered for residential and commercial applications, this 100-amp main breaker establishes the primary disconnect for your electrical system. It installs into Type CH load centers, as well as ECC and ECB unit enclosures, utilizing a secure bolt-on connection. Featuring a 25kAIC rating at 120/240V, the thermal-magnetic unit provides reliable long-time and instantaneous trip functions. Note that this specific model has been superseded by the CSR2100N kit.
Type CH Load Centers, Type ECC Unit Enclosures, Type ECB Unit Enclosures
Wire Gauge
#2 AWG - 300 kcmil
Max Wire
300 kcmil
Min Wire
2 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed
Standards and features
Available Options
Shunt Trip, Auxiliary Switch, Alarm Switch
Accessories
Lugs Included
Standards
CSA C22.2 No. 5, UL 489
Approval
CSA, UL
Temp Rating
40C
Construction Features
Main Breaker, HACR Rated
Product FAQs
8 answers
What load centers are compatible with the Eaton CSR2100 main breaker?
This breaker is designed for use as a main breaker in Eaton Type CH load centers. It is also compatible with Type ECC and ECB unit enclosures.
Can the CSR2100 replace an older BWH2100 main breaker?
Yes. The CSR2100 and BWH2100 share the same physical footprint and 25kAIC rating. They can be interchanged as long as your load center publication lists both types.
What is the difference between the CSR2100 and the CSR2100N?
The CSR2100N is the newer catalog kit number for the same breaker. Both share the exact same physical dimensions, 100-amp rating, and 25kAIC interrupting capacity.
Is the CSR2100 interchangeable with a BW2100 breaker?
While they share the same physical footprint, the BW2100 has a lower 10kAIC interrupting rating. The CSR2100 provides a higher 25kAIC rating and can replace the BW2100 if the panel labeling permits it.
What wire sizes are accepted by the lugs on the CSR2100?
The oversized load-side lugs on this breaker accept copper or aluminum wire ranging from 2 AWG up to 300 kcmil.
How does this main breaker mount inside the panel?
The CSR2100 features a base mount, bolt-on design that secures directly to the bus in compatible Type CH load centers and enclosures.
What type of trip mechanism does the CSR2100 use?
It utilizes a fixed thermal-magnetic trip unit, providing both long-time overload protection and instantaneous short-circuit protection.
Can this breaker be used as a service disconnect?
Yes, when properly installed in an approved main breaker enclosure or load center, it serves as the primary service disconnect for the electrical system.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.