Eaton / Cutler-HammerFAZ-D5/2-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D5/2-NA
Eaton / Cutler-HammerFAZ-C1/2-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-C13/2-NA |
| Series | FAZ-NA |
| Amperage | 13A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG (1 wire), 18-10 AWG (2 wires) |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | C |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Lockout Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | ABS, CE, CSA, DNV, IEC, Lloyd's, RoHS, UL, VDE |
| Temp Rating | -40C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism, Visual Trip Indicator |
The C-curve magnetic trip characteristic means the breaker will trip instantaneously at 5 to 10 times the rated current. This makes it ideal for applications with medium inrush currents, such as small transformers, lighting, pilot devices, and control circuits.
The -NA suffix indicates that the breaker is UL 489 listed for branch circuit protection in North America. Standard FAZ breakers without this designation are typically UL 1077 recognized as supplementary protectors. UL 489 devices can be used in place of UL 1077 protectors, but not vice versa.
Yes, Eaton FAZ-NA miniature circuit breakers are suitable for reverse feed applications, allowing line power to be supplied to either the top or bottom terminals.
Yes, the FAZ-NA series features a current limiting design. It interrupts fault currents within one half cycle, which significantly reduces the peak let-through energy that could otherwise damage downstream circuit components.
Yes, the FAZ-NA series supports a variety of subsequent mounting accessories, including auxiliary contacts, alarm switches, shunt trips, and lockout attachments. These mount directly to the side of the breaker without requiring special tools.
This breaker mounts to a standard 35mm DIN rail. It utilizes a spring clip mechanism for secure attachment and easy removal within control panels.
Yes, this breaker is HACR rated, meaning it is approved for use with heating, air conditioning, and refrigeration equipment.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.