Engineered for commercial and industrial use, this 30-amp miniature circuit breaker delivers dependable branch circuit protection. It is optimized for applications where medium levels of inrush current are expected. The single-pole breaker is designed to mount effortlessly onto standard DIN rail systems and industrial control panels. It features finger-safe box lug terminals for secure connections. With a 10 kAIC rating at 277VAC, the unit utilizes a C-curve thermal-magnetic trip mechanism.
What does the C-curve trip characteristic mean for this Eaton breaker?
The C-curve designation indicates a magnetic trip point between 5 and 10 times the 30A rated current. This makes it suitable for medium inrush current applications like small transformers, lighting, and control circuits.
What is the difference between the FAZ-NA series and standard FAZ breakers?
The NA in the FAZ-C30/1-NA-SP part number signifies that it is a UL 489 listed device. This means it is approved for primary branch circuit protection in North America, whereas standard UL 1077 FAZ breakers are only rated as supplementary protectors.
Can I reverse feed the FAZ-C30/1-NA-SP?
Yes, this miniature circuit breaker is designed to allow power to be fed from either the line or the load side, providing flexibility when wiring DIN rail panels or industrial control panels.
How much DIN rail space does the FAZ-C30/1-NA-SP require?
This single-pole breaker requires 17.7mm of width on a standard 35mm DIN rail.
How does the current-limiting design of this breaker protect equipment?
The current-limiting design interrupts fault currents within one half cycle. This rapid response significantly reduces the peak let-through current and energy, offering superior protection against circuit damage compared to standard non-limiting breakers.
Does the FAZ-C30/1-NA-SP have a trip-free mechanism?
Yes, it features a trip-free design. This ensures the breaker will still trip and interrupt the circuit during an overcurrent or short-circuit fault even if the toggle handle is physically held in the ON position.
What does the SP suffix mean in the FAZ-C30/1-NA-SP part number?
The SP indicates single packaging. The breaker itself is identical in form, fit, and function to the standard FAZ-C30/1-NA, but it is packaged individually rather than in bulk quantities.
How do I verify the contact status of this breaker?
The breaker includes a color-coded visual indicator on the front face. It displays red when the contacts are closed and power is ON, and green when the contacts are open and isolated for OFF.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 2.0 out of 5 based on 2 reviews.