Designed specifically for marine and corrosive environments, this specialized 70-amp F-Frame breaker utilizes robust stainless steel terminals. It fastens securely into Eaton Series C panelboards, industrial switchboards, and motor control centers. The S01 suffix denotes these upgraded terminal connections for demanding commercial applications. Offering a 14kAIC rating at 480V, the thermal-magnetic unit features a factory-installed shunt trip and supports reverse feed operations.
What do the L and S01 suffixes mean in the FDB3070LS01 catalog number?
The L indicates that both line and load lugs are factory installed, whereas standard F-Frame breakers typically ship with load terminals only. The S01 designates a factory installed shunt trip in the left pole, rated for 12 to 24V AC/DC, with 18-inch pigtail leads exiting the same side.
What are the physical dimensions of this 3-pole F-Frame breaker?
The FDB3070LS01 measures 6.00 inches tall, 4.13 inches wide, and 3.38 inches deep. These standard F-Frame dimensions allow it to fit seamlessly into compatible Eaton chassis and backpans.
Which Eaton enclosures and systems accept the FDB3070LS01?
This F-Frame breaker is designed for installation in Eaton Series C panelboards, switchboards, and motor control centers. It requires a unit mount configuration, meaning it bolts directly to a backpan rather than plugging onto a busbar.
Is the FDB3070LS01 suitable for DC circuits?
Yes, this breaker is rated for use on DC systems up to 250VDC, providing a 10kA interrupting capacity. When used in DC applications, follow Eaton guidelines for wiring multiple poles in series if required by the system voltage.
Can this F-Frame circuit breaker be reverse fed?
Yes, standard Eaton Series C thermal magnetic breakers like the FDB3070LS01 do not have line and load restrictions. They can be reverse fed, allowing power to be supplied to either set of terminals safely.
Is the FDB3070LS01 rated for HVAC equipment?
Yes, this breaker is HACR rated, meaning it is tested and approved for the specific inrush currents and operational demands of heating, air conditioning, and refrigeration equipment.
Are the trip settings adjustable on the FDB3070LS01?
No, this breaker features a fixed thermal and fixed magnetic trip unit. It provides standard Long-Time and Instantaneous (LI) protection, but the trip thresholds cannot be field adjusted.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 2 reviews.