Built for heavy-duty industrial environments, this 20A G-frame breaker monitors circuits for 30mA ground fault leakage. This equipment-level threshold protects expensive motors and machinery without the frequent interruptions common to 5mA personnel GFCI units. Installation is streamlined for OEM control panels and Eaton Series C enclosures via its unit-mount design.
Eaton Series C Enclosures, OEM Panels, DIN Rail (with adapter)
Wire Gauge
14-10 AWG
Max Wire
10 AWG
Min Wire
14 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LIG
Trip Function
Long-Time, Instantaneous, Ground Fault
Trip Adjustability
Fixed Thermal, Fixed Magnetic
Standards and features
Special Classification
GFEP
Available Options
Padlock Attachment
Accessories
Line and Load Lugs Included
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CSA, UL
Temp Rating
40C
Construction Features
HACR Rated
Product FAQs
7 answers
What enclosures or panels is the GHCGFEP1020 compatible with?
This breaker is designed for use in Eaton Series C enclosures and OEM panels. It can also be mounted on a standard 35mm DIN rail using a separate adapter kit.
What is the DIN rail adapter part number for this 1-pole GHC breaker?
To mount this 1-pole breaker on a standard 35mm DIN rail, you will need Eaton adapter kit part number 1225C79G01.
What is the ground fault trip sensitivity for the GHCGFEP1020?
This is a Ground Fault Equipment Protection (GFEP) breaker with a 30 mA trip sensitivity. It is designed to protect equipment from damaging line-to-ground faults rather than for personnel protection.
Can this breaker be used in DC applications?
Yes, the GHCGFEP1020 is rated for 125VDC with an interrupting capacity of 14kAIC, in addition to its standard 277VAC rating.
What is the purpose of the pigtail neutral on this breaker?
The pigtail wire must be connected to the panel neutral bar to power the internal ground fault sensing circuitry.
What wire sizes are accepted by the lugs on this 20A breaker?
The terminals on this breaker accept wire ranging from 14 AWG to 10 AWG.
Is this breaker suitable for personnel protection in wet locations?
No. This is a 30 mA GFEP breaker intended for equipment protection, such as heat trace cables. It does not provide the 5 mA Class A GFCI protection required for personnel safety in wet areas.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 1 review.