Eaton / Cutler-Hammer HFDDC3175W Molded Case Circuit Breaker

  • 175A
  • 3 Pole
  • Panel Mount
Eaton / Cutler-Hammer HFDDC3175W
Molded Case Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU HFDDC3175W
Select Item Condition
Earn 2031 SuperPoints
  • 175A
  • 3 Pole
  • Panel Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Eaton / Cutler-Hammer HFDDC3175W - 175A 3 Pole Molded Case Circuit Breaker

New

$2,031.42 In Stock

Quantity

Description

Built specifically for photovoltaic systems, the HFDDC3175W is a 3-pole, 175A molded case circuit breaker from Eaton's Series C F-Frame family. It is designed for industrial environments, offering robust performance in solar combiner boxes. This unit installs into Eaton Series C panelboards. Supplied without terminals (W suffix), it allows for custom lug configurations. Rated 42kAIC at 600V, it features fixed thermal-magnetic trip units for dependable LI defense.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Part Number HFDDC3175W
Series HFDDC
Amperage 175A
Poles 3
Mounting Style Panel Mount
Voltage 600VAC, 250VDC, 600VDC
Phase 3
AIC Rating 42kA @ 600VAC, 42kA @ 250VDC, 42kA @ 600VDC
Fit and installation
Frame Type HFDDC
Terminal Type Lugs
For Use With Eaton Series C Panelboards, Solar Combiner Boxes
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits
Accessories Without Terminals
Standards UL 489, UL 489B
Approval CSA, UL
Temp Rating 40C
Construction Features Photovoltaic Rated, 50C Ambient Calibration, Reverse Feed, Non-Interchangeable Trip, High Interrupting Capacity

Product FAQs

8 answers
Does the HFDDC3175W come with mounting lugs?

No. The W suffix in the catalog number indicates this breaker is supplied without line or load terminals. Lugs must be sourced and installed separately based on your specific wire size and material requirements.

What frame size is the Eaton HFDDC3175W?

This breaker is part of the Eaton Series C F-Frame family. It shares the same physical footprint as other F-Frame breakers, allowing for straightforward integration into existing F-Frame panel spaces.

Can the HFDDC3175W be used in direct current (DC) systems?

Yes. It is specifically rated for both AC and DC systems, making it highly suitable for solar combiner boxes and photovoltaic applications. It provides a 42kA interrupting capacity at both 250VDC and 600VDC.

How does this breaker mount into a panelboard?

The HFDDC3175W is a bolt-on circuit breaker. It secures directly to the busbar using mechanical fasteners in compatible Eaton Series C panelboards and switchboards.

Is the trip unit on the HFDDC3175W adjustable?

No. This breaker is equipped with a thermal-magnetic trip unit featuring fixed long-time (thermal) and fixed instantaneous (magnetic) trip functions. It cannot be adjusted in the field.

What equipment accepts the HFDDC3175W breaker?

It is designed for use in Eaton Series C panelboards, switchboards, motor control centers, and solar combiner boxes that are configured to accept F-Frame molded case circuit breakers.

Are Eaton Series C F-Frame breakers suitable for reverse feeding?

Yes. Standard Eaton F-Frame thermal-magnetic circuit breakers, including the HFDDC series, are suitable for reverse feed applications.

What is the difference between the HFDDC3175W and the HFDDC3175L?

The W suffix indicates the breaker is supplied without terminals. The HFDDC3175L is the exact same 175A breaker but comes factory-equipped with standard line and load lug terminals.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.