Skip to main content
Expedited shipping available at checkout

Eaton / Cutler-Hammer HKDDC3225 Molded Case Circuit Breaker

  • 225A
  • 3 Pole
  • Unit Mount
Eaton / Cutler-Hammer HKDDC3225
Molded Case Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU HKDDC3225
Select Item Condition
Earn 4640 SuperPoints
  • 225A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Eaton / Cutler-Hammer HKDDC3225 - 225A 3 Pole Molded Case Circuit Breaker

New

$4,640.00 In Stock

Quantity

Description

Part of the Series C family, the Eaton HKDDC3225 is a 225A, 3-pole MCCB engineered for demanding DC environments. It is designed for industrial facilities, data centers, and solar PV systems requiring robust protection. This unit-mount breaker installs into Eaton Series C panelboards, switchboards, and motor control centers. It includes standard lug terminals for secure connections. Rated for 42kAIC at 600VDC, this K-Frame breaker features thermal-magnetic trip technology and PV Guard.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Series HKDDC
Amperage 225A
Poles 3
Mounting Style Unit Mount
Voltage 125VDC, 250VDC, 600VDC
Phase 3
AIC Rating 42kA @ 125VDC, 50kA @ 250VDC, 42kA @ 600VDC
Fit and installation
Frame Type K
Terminal Type Lugs
For Use With Eaton Series C Panelboards, Switchboards, Motor Control Centers
Wire Gauge 3 AWG - 350 kcmil (Cu/Al)
Max Wire 350 kcmil
Min Wire 3 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Terminal Shields
Accessories Lugs
Standards CSA C22.2 No. 5, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features DC Rated, High Interrupting Capacity, PV Guard

Product FAQs

6 answers
Can I install the HKDDC3225 in a standard Eaton load center?

No. This is a K-Frame molded case circuit breaker designed for commercial and industrial Eaton Series C panelboards, switchboards, and motor control centers. It will not fit in standard residential load centers.

Is the HKDDC3225 rated for AC applications?

The HKDDC series is specifically engineered and tested for heavy-duty DC environments, such as solar photovoltaic systems and data centers, with a maximum rating of 600VDC. It is not intended for standard AC circuits.

How is the trip unit configured on the HKDDC3225?

It features a thermal-magnetic trip unit with a fixed thermal element for long-time overload protection and an adjustable magnetic element for instantaneous short-circuit protection. This allows electricians to fine-tune the instantaneous trip threshold based on the specific DC load.

How should the poles be wired for 600VDC applications?

For maximum voltage and interruption ratings in DC systems, multiple poles must be connected in series. Always refer to Eaton installation guidelines for proper series wiring configurations based on whether your system is grounded or ungrounded.

What is the difference between the standard HKD3225 and the HKDDC3225?

The standard HKD3225 is primarily designed for AC systems. The HKDDC3225 is specifically rated for high-voltage DC applications up to 600VDC, making it the correct choice for photovoltaic arrays, battery energy storage, and industrial DC circuits.

What safety precautions are required for reverse feed applications?

When using this breaker in reverse feed applications, special attention must be paid during maintenance. Electricians must verify that no voltage is present on either the line or load terminals before inspecting or servicing the equipment.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.