Eaton / Cutler-Hammer LGE360032G Molded Case Circuit Breaker

  • 600A
  • 3 Pole
  • Unit Mount
Eaton / Cutler-Hammer LGE360032G
Molded Case Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU LGE360032G
Select Item Condition
Earn 5434 SuperPoints
  • 600A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Eaton / Cutler-Hammer LGE360032G - 600A 3 Pole Molded Case Circuit Breaker

New

$5,434.72 In Stock

Quantity

Description

Engineered for commercial and industrial power distribution, this 600A molded case circuit breaker utilizes microprocessor-based sensing for accurate overcurrent protection. It installs into Eaton Series G panelboards, switchboards, and motor control centers using standard unit mounting. The adjustable long-time, short-time, and instantaneous (LSI) settings allow facility managers to fine-tune coordination, while the 35kAIC rating at 480VAC handles demanding fault conditions.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Series LGE
Amperage 600A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 65kA @ 240VAC, 35kA @ 480VAC, 18kA @ 600VAC
Fit and installation
Frame Type LG
Terminal Type Lugs
For Use With Eaton Series G Panelboards, Switchboards, Motor Control Centers
Wire Gauge (2) 2 AWG - 500 kcmil (Cu/Al)
Max Wire 500 kcmil
Min Wire 2 AWG
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LSI
Trip Function Long-Time, Short-Time, Instantaneous
Trip Adjustability Adjustable
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator, Handle Lock, Padlock Attachment
Accessories Line and Load Terminals
Standards CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489
Approval CE, CSA, IEC, UL
Temp Rating 40C
Construction Features HACR Rated, Current Limiting, 80% Rated, True RMS Sensing

Product FAQs

9 answers
What does the 32G suffix in the LGE360032G catalog number indicate?

The 32 indicates the breaker is equipped with a Digitrip 310+ electronic trip unit featuring LSI (Long-Time, Short-Time, and Instantaneous) protection. The G signifies that standard line and load terminals are included.

What adjustments can be made on the Digitrip 310+ LSI trip unit?

The LSI electronic trip unit allows you to adjust the Long-Time pickup and delay, Short-Time pickup and delay, and Instantaneous pickup to coordinate with other protective devices in your electrical system.

Does the Digitrip 310+ trip unit have a test port?

Yes, the Digitrip 310+ includes a test port that allows you to perform a no-trip functional test using an Eaton test kit. The test LED also functions as a high load alarm indicator during normal operation.

What types of enclosures and equipment are compatible with the LGE360032G?

This LG-frame breaker is designed for use in Eaton Series G panelboards, switchboards, and motor control centers.

Does the LGE360032G come with mounting hardware and lugs?

Yes, the G suffix in the catalog number indicates that standard aluminum line and load lugs are factory-installed.

What is the recommended torque for the terminal mounting screws on the LG frame?

When securing the wire connecting terminals to the circuit breaker, Eaton recommends torquing the cap screws to 6 to 8 lb-ft.

Is it safe to install or perform maintenance on the LGE360032G while the panel is energized?

No. Always verify that no voltage is present before proceeding with installation or maintenance. Contact with energized equipment can result in severe personal injury or death.

Can the Series G LG-frame breaker directly replace an older Series C L-frame breaker?

While the Series G LG-frame covers similar amperage ranges as the legacy Series C L-frame, they have different physical dimensions and mounting footprints. Retrofit kits or panel modifications are typically required when replacing older L-frame units.

What is the maximum continuous current rating for the LG frame?

The LG frame has a maximum continuous current rating of 630 amps globally, but it is limited to 600 amps for UL and CSA listed applications.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.