Eaton / Cutler-Hammer PDG22G0045TFFL - 45A 2 Pole Molded Case Circuit Breaker

Eaton / Cutler-Hammer PDG22G0045TFFL - 45A 2 Pole Molded Case Circuit Breaker

Re-Certified

$362.31 No Stock

Quantity

Similar Items

Description

Engineered for industrial applications, the Eaton PDG22G0045TFFL is a 2-pole, 45A molded case circuit breaker from the Power Defense family. It provides reliable overcurrent protection for demanding electrical systems. This panel-mount MCCB installs into Eaton Frame 2 enclosures and panelboards. It serves as a direct replacement for legacy FD2045 breakers, ensuring a seamless upgrade path. Rated at 35kAIC at 480VAC, the unit features a fixed thermal-magnetic (LI) trip and load-side lugs.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Series PDG2
Amperage 45A
Poles 2
Mounting Style Panel Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 1
AIC Rating 65kA @ 240VAC, 35kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC
Fit and installation
Frame Type Complete Breaker
Terminal Type Lugs
For Use With Eaton Power Defense Frame 2 Enclosures and Panelboards
Wire Gauge 14-1/0 AWG (Al/Cu)
Max Wire 1/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Terminal Shields
Accessories Load Side Lugs (PDG2X2T100)
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS
Approval CCC, CE, CSA, IEC, RoHS, UL
Temp Rating -20C to 70C
Construction Features HACR Rated, RoHS Compliant

Product FAQs

6 answers
What wire sizes are accepted by the standard lugs on the PDG22G0045TFFL?

The factory-installed line and load lugs accept 14 AWG to 1/0 AWG wire. Ensure proper torque specifications are followed during installation for both aluminum and copper conductors.

Are the trip settings on the PDG22G0045TFFL adjustable?

No. This breaker features a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous trip functions are factory-set and cannot be modified in the field.

What does the G in the PDG22G0045TFFL catalog number signify?

The G indicates that this is a globally rated Power Defense breaker. Unlike the PDD series which is UL and CSA only, PDG breakers meet UL, CSA, IEC, and CCC standards for international use.

What does the TFFL suffix mean in the catalog number?

In the Power Defense nomenclature, TFFL indicates a thermal-magnetic trip unit (T) with fixed thermal (F) and fixed magnetic (F) settings, equipped with standard line and load lugs (L).

Can I install field accessories like auxiliary switches on this breaker?

Yes. The PDG22G0045TFFL accepts standard Power Defense Frame 2 internal and external accessories, such as the PDGXAC auxiliary switch and PDG2XPLKT padlock hasp.

Does this thermal-magnetic breaker support the Arcflash Reduction Maintenance System (ARMS)?

No. The ARMS feature is only available on Power Defense breakers equipped with advanced Power Xpert Release (PXR) electronic trip units. This model uses a standard fixed thermal-magnetic trip unit.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.