Engineered for commercial and industrial applications, the Eaton PDG33G0600E2MJ is a 600A electronic trip molded case circuit breaker. It provides reliable power distribution and advanced system monitoring within Power Defense Frame 3 panelboards and switchboards. This panel-mount MCCB serves as an exact replacement for legacy LGS360032G breakers. It utilizes standard line and load lugs for secure wire terminations. Rated 35kA at 480VAC, it features a PXR20 LSI trip unit with Modbus RTU.
Standard Line and Load Terminals (PDG3X3TA630), Modbus/Relay Module
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CCC, CE, CSA, IEC, UL, RoHS
Temp Rating
-20C to 70C
Construction Features
HACR Rated, RoHS Compliant, True RMS Sensing
Product FAQs
7 answers
What older Eaton or Cutler-Hammer breaker frames does the Power Defense Frame 3 replace?
The Power Defense Frame 3 platform upgrades and replaces legacy Eaton Series G breakers, providing modern PXR electronic trip units while maintaining a familiar footprint.
What do the "E2MJ" characters signify in the PDG33G0600E2MJ catalog number?
"E2" indicates a PXR20 electronic trip unit with LSI (Long-Time, Short-Time, Instantaneous) protection. "M" signifies the inclusion of Modbus RTU communications and relays. "J" denotes standard line and load terminals (PDG3X3TA630).
What does the "G" in the PDG33G0600E2MJ catalog number indicate?
The "G" indicates the breaker's interrupting rating, which is 35 kAIC at 480VAC. For comparison, an "M" in this position would indicate a higher 65 kAIC rating at 480VAC.
What is the recommended torque for the standard line and load terminals on this 600A breaker?
The standard PDG3X3TA630 lugs included with this breaker accept two 2 AWG to 500 kcmil aluminum or copper wires per phase. The terminal screws should be torqued to 375 in-lbs (42.4 N-m).
Can the PDG33G0600E2MJ be reverse fed?
Yes, Power Defense Frame 3 breakers can be reverse fed when ordered as a complete, factory-assembled breaker like the PDG33G0600E2MJ. Note that if the frame and trip unit are ordered separately, reverse feeding is not permitted.
What enclosures or panelboards is the PDG33G0600E2MJ compatible with?
This breaker is designed for use in Eaton Power Defense Frame 3 panelboards and switchboards. It is also compatible with NEMA 1, 3R, 12, and 4X standalone enclosures designed for Frame 3 breakers.
How does the Modbus RTU communication work on the PDG33G0600E2MJ?
The integrated PXR20 trip unit includes Modbus RTU communications and relays, allowing the breaker to transmit predictive diagnostics, load alarms, and breaker health data directly to a facility's power management system without requiring separate communication components.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.