Eaton / Cutler-HammerQBHGFEP2020
Quantity
New
Quantity
Eaton / Cutler-HammerQBHGFEP2020
Eaton / Cutler-HammerQBH1020EP
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | QBHGFEP |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC |
| Phase | 1 |
| AIC Rating | 22kA @ 120VAC |
| Frame Type | BAB |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Pow-R-Line Panelboards |
| Wire Gauge | 14-4 AWG |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFEP |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2, UL 1053, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, High Interrupting Capacity, SWD Rated |
This bolt-on breaker is designed for Eaton and Cutler-Hammer Pow-R-Line panelboards, including the PRL1a and PRL2a series, that accept Quicklag BAB or QB frame breakers.
No. This is a bolt-on breaker engineered specifically for commercial and industrial Pow-R-Line panelboards. It is not compatible with plug-on residential load centers like the Eaton BR or CH series.
This Ground Fault Equipment Protector (GFEP) features a 30mA trip sensitivity. It is calibrated to protect machinery and heat trace cables from equipment-damaging ground faults, rather than providing 5mA personnel protection.
Yes, this breaker is HACR rated, making it approved for use with heating, air conditioning, and refrigeration equipment that requires 30mA ground fault equipment protection.
This breaker includes a factory-installed pigtail neutral wire. During installation, the pigtail must be routed and secured to the neutral bar in the panelboard to power the internal ground fault circuitry.
The "H" in the QBHGFEP1020 catalog number designates a high interrupting capacity. The QBHGFEP1020 provides a 22kAIC rating at 120V, while the standard QBGFEP1020 is rated for 10kAIC.
No. The QBHGFEP1020 is an equipment protection device with a 30mA trip level. It cannot be used in place of a Class A GFCI, which has a 5mA trip level, for applications requiring personnel protection such as bathrooms, kitchens, or swimming pools.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.