Square D CF2020 2 Pole Circuit Breaker

Eaton / Challenger CF2020 - 20A 2 Pole Molded Case Circuit Breaker

Re-Certified

$188.76 No Stock

Quantity

Description

Designed to maintain existing infrastructure, this 2-pole, 20A molded case circuit breaker is part of Eaton's legacy Challenger series. It provides essential thermal-magnetic protection for commercial facilities operating on 600VAC systems. The unit mount design integrates seamlessly into older Challenger, Westinghouse, and Eaton panelboards. For modern upgrades, this F-frame configuration crosses over to the FD2020 replacement model.

Specifications

Key specifications
Brand Eaton / Challenger
Part Number CF2020-R
Series CF
Amperage 20A
Poles 2
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 1
AIC Rating 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC
Fit and installation
Terminal Type Lugs
For Use With Challenger Panelboards, Eaton Panelboards, Westinghouse Panelboards
Wire Gauge #14-1/0 AWG
Max Wire 1/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch
Accessories Load Side Lugs Included
Standards CSA C22.2 No. 5, NEMA AB 1, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features HACR Rated

Product FAQs

9 answers
Which panelboards are designed to accept this CF frame breaker?

This breaker is engineered for compatibility with legacy commercial and industrial panelboards manufactured by Challenger, Westinghouse, and Eaton that are specifically configured for unit mount CF frame devices.

What wire sizes are accepted by the lugs on the CF2020?

The factory-installed lugs accommodate conductors ranging from 14 AWG up to 1/0 AWG. Installers must ensure proper torque is applied to the terminals to maintain a secure connection and prevent thermal issues.

How is the CF2020 secured inside an electrical enclosure?

This device features a unit mount configuration. It requires bolting directly to the backpan or mounting plate of the panelboard, rather than snapping onto a busbar like plug-on residential breakers.

Is this breaker suitable for direct current systems?

Yes, in addition to its AC ratings, this thermal magnetic breaker is certified for use in DC systems up to 250VDC, where it delivers a 10kA interrupting capacity.

What type of protection does the LI trip unit provide?

The LI designation indicates Long-Time and Instantaneous protection. The fixed thermal element handles Long-Time overload conditions, while the fixed magnetic element responds immediately to Instantaneous short-circuit faults.

What is the modern replacement for this legacy Challenger breaker?

The CF2020 is part of a legacy molded case circuit breaker family. For modern upgrades or replacements in compatible enclosures, Eaton's FD2020 is often used as the current F-frame equivalent.

Can I use this breaker to replace an older Westinghouse CF2020?

Yes. Because Eaton acquired the distribution equipment lines of both Westinghouse and Challenger, this CF2020 is a direct replacement for original Westinghouse and Challenger CF frame breakers sharing the same catalog number.

What safety functions does the thermal magnetic mechanism serve?

The thermal magnetic trip unit provides dual-level safety. The bimetallic thermal component prevents overheating from prolonged overloads, while the electromagnetic assembly quickly clears severe short circuits to protect downstream wiring.

Can this breaker be installed in systems with high available fault current?

It can be used in systems with up to 65kA of available fault current when operating at 240VAC. However, the interrupting capacity drops to 25kA at 480VAC and 18kA at 600VAC, so the system voltage must be evaluated during coordination.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.