ABB T5H400TW Molded Case Circuit Breaker

  • 400A
  • 3 Pole
  • Unit Mount
ABB T5H400TW
Molded Case Circuit Breaker
Brand ABB
SKU T5H400TW
Select Item Condition
Earn 3480 SuperPoints
  • 400A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

ABB T5H400TW - 400A 3 Pole Molded Case Circuit Breaker

New

$3,480.00 In Stock

Quantity

Description

Delivering high interrupting capacity, the ABB T5H400TW is a 400A, 3-pole molded case circuit breaker. It features a thermal magnetic trip unit with fully adjustable settings, allowing precise calibration for specific load requirements. This unit mount breaker is engineered for ABB ReliaGear panelboards and motor control centers. It is replaced by the XT5HU340ABFF000XXX via a retrofit kit. Boasting a 150kAIC rating at 240VAC, it includes double insulation and is reverse feed compatible.

Specifications

Key specifications
Brand ABB
Part Number T5H400TW
Series T5
Amperage 400A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC, 500VDC, 600VDC
Phase 3
AIC Rating 150kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 65kA @ 250VDC, 50kA @ 500VDC, 35kA @ 600VDC
Electrical ratings
Amperage Range 280-400A
Fit and installation
Frame Type T5
Terminal Type Lugs
For Use With ABB ReliaGear Panelboards, Switchboards, Motor Control Centers
Wire Gauge (2) 2/0 AWG - 250 kcmil
Max Wire 250 kcmil
Min Wire 2/0 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Adjustable Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Motor Operator, Mechanical Interlock, Lug Kits, Terminal Shields, Bell Alarm
Accessories Front Terminals Included, Lugs Not Included
Standards CSA C22.2 No. 5.1, IEC 60947-2, UL 489
Approval CE, CSA, IEC, UL
Temp Rating 40C
Construction Features HACR Rated, Reverse Feed, High Interrupting Capacity, Positive Operation

Product FAQs

10 answers
What equipment is the T5H400TW designed to be installed in?

This breaker is engineered for integration into ABB ReliaGear panelboards, switchboards, and motor control centers. It utilizes a bolt-on connection for secure unit mounting within these enclosures.

What wire sizes are accepted by the factory lugs on this breaker?

The included lugs accept two conductors per phase, accommodating wire sizes from 2/0 AWG to 250 kcmil. Ensure proper torque specifications are applied during installation.

How does the adjustable thermal magnetic trip unit function on this model?

The T5H400TW features a Long-Time and Instantaneous (LI) trip configuration. This allows electricians to manually adjust both the thermal threshold for overload protection and the magnetic threshold for short-circuit response, providing precise calibration for specific load requirements.

Can the T5H400TW be used in DC power systems?

Yes, this breaker is rated for DC applications. It provides an interrupting capacity of 65kA at 250VDC, 50kA at 500VDC, and 35kA at 600VDC.

What does the H in the T5H400TW part number signify?

In the ABB SACE Tmax nomenclature, the H designates the High interrupting capacity tier. For this 400A frame, it delivers a maximum interrupting rating of 150kA at 240VAC and 65kA at 480VAC.

Can this breaker be reverse fed?

Yes, ABB Tmax series molded case circuit breakers can be fed from either the top or bottom terminals without any derating of their performance characteristics, making them suitable for reverse feed applications.

Does the mounting orientation affect the performance of the breaker?

No, the T5H400TW can be installed in either horizontal or vertical planes within panels and switchboards without derating its electrical performance.

Is this breaker part of the current ABB lineup or a legacy series?

The T5H400TW belongs to the legacy ABB SACE Tmax T5 frame series. It is commonly used to replace existing T5 breakers in older installations or for maintaining standardized equipment in existing facilities.

Does this breaker support the safe installation of internal accessories?

Yes, the T5H400TW features a double insulation construction. This design allows for the field installation of internal electrical accessories without exposing the installer to the energized power poles.

How does the toggle mechanism ensure safe operation?

The breaker features positive operation, meaning the toggle handle always indicates the precise physical position of the moving contacts. This guarantees safe and reliable visual signaling for maintenance personnel.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.