Combining four poles into a compact two-space footprint, the THQLQ151515 quadplex breaker delivers efficient power distribution for residential and commercial applications. It features two 15A single-pole outer circuits and one 15A double-pole inner circuit. This plug-on unit installs into ABB ReliaHome, GE PowerMark Gold, and PowerMark Plus load centers. Rated for 10kAIC at 120/240VAC, it includes a common trip on the center poles and is HACR and SWD rated for switching duty.
ABB ReliaHome Load Centers, GE PowerMark Gold Load Centers, GE PowerMark Plus Load Centers
Wire Gauge
14-8 AWG (Cu), 12-8 AWG (Al)
Max Wire
8 AWG
Min Wire
14 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed
Standards and features
Special Classification
Quadplex
Available Options
Padlock Attachment, Handle Tie
Standards
HACR, SWD, UL 489
Approval
cUL, UL
Temp Rating
40C
Product FAQs
6 answers
Can I use the ABB THQLQ151515 to replace an older GE THQLQ151515?
Yes. ABB acquired GE Industrial Solutions, and this breaker is a direct, code-compliant replacement for the legacy GE THQLQ151515. It is fully compatible with GE PowerMark Gold and PowerMark Plus load centers.
How much panel space does this quadplex breaker occupy?
The THQLQ151515 requires two standard 1-inch spaces (2 inches total) in a compatible load center. It provides four poles of protection, maximizing circuit density without requiring a subpanel.
Does this breaker require a panel with rejection clips or wing stabs?
No. The THQLQ151515 features a standard plug-on connection that does not require half-inch wing stabs, allowing it to be placed in any standard slot within a compatible ABB or GE panelboard.
How are the 15A circuits configured on this quad breaker?
The breaker houses two independent 1-pole 15A circuits on the outer poles and one 2-pole 15A circuit on the inner poles. The center 2-pole configuration features a common trip mechanism for 240V loads.
Do the center poles on the THQLQ151515 feature a common trip?
Yes, the inner 2-pole 15A circuit utilizes a common trip mechanism. If one leg of the 240V circuit experiences an overload or short circuit, both center poles will trip simultaneously to safely disconnect the load.
Is the THQLQ151515 rated for switching duty and HVAC applications?
Yes, this breaker carries both SWD (Switching Duty) and HACR (Heating, Air Conditioning, and Refrigeration) ratings, making it suitable for controlling fluorescent lighting circuits and HVAC equipment.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.