Delivering robust protection, the XT1SU3070AFD000XXX is a 3-pole, 70A MCCB from ABB's SACE Tmax XT family. It meets the rigorous demands of industrial infrastructure. Designed for unit mount configurations, it installs into ReliaGear SB switchboards and enclosures. It serves as a direct replacement for discontinued T1S070TL breakers. The breaker features a fixed thermal-magnetic trip unit with a 35 kAIC rating at 480VAC. It is HACR rated, current limiting, and includes load side lugs.
Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Motor Operator
Accessories
Load Side Lugs
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CE, CSA, cULus, IEC, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Current Limiting, Reverse Feed, Double Insulated
Product FAQs
8 answers
How is this breaker mounted in ReliaGear SB switchboards?
It utilizes a unit mount configuration, allowing it to be bolted directly into ABB and GE ReliaGear SB switchboards or compatible standalone enclosures.
What legacy breaker does the XT1SU3070AFD000XXX replace?
This model serves as a direct replacement for the discontinued GE and ABB T1S070TL circuit breakers.
Is this breaker rated for HVAC equipment?
Yes, it carries a HACR rating, meaning it is certified for use with heating, air conditioning, and refrigeration systems.
What does the LI trip function indicate on this breaker?
The LI designation means the fixed thermal-magnetic trip unit provides both Long-Time overload protection and Instantaneous short-circuit protection.
Do I need to purchase separate lugs for this breaker?
No, it comes standard with load side lugs that accept 10 AWG to 2/0 AWG copper or aluminum wiring, making it ready for immediate installation.
Is this XT1 breaker current limiting?
Yes, it features a current-limiting design that restricts the peak let-through current during a fault, providing enhanced protection for downstream circuits.
Can this breaker be reverse fed?
Yes, this breaker is reverse feed capable, allowing you to wire the line connections to either the top or bottom terminals depending on your panel layout.
What does the S in the XT1S frame designation mean?
The S indicates a standard interrupting capacity, which provides a 35 kAIC rating at 480VAC for this specific model.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.