Skip to main content
Expedited shipping available at checkout

ABB / General Electric SGPA36AT4400C Molded Case Circuit Breaker

  • 400A
  • 3 Pole
  • Unit Mount
ABB / General Electric SGPA36AT4400C
Molded Case Circuit Breaker
Brand ABB / General Electric
SKU SGPA36AT4400C
Select Item Condition
Earn 4485 SuperPoints
  • 400A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

ABB / General Electric SGPA36AT4400C - 400A 3 Pole Molded Case Circuit Breaker

New

$4,485.60 In Stock

Quantity

Description

Engineered for industrial power distribution, the GE SGPA36AT4400C 3-pole, 400A molded case circuit breaker belongs to the Spectra RMS series. It delivers reliable performance for heavy-duty applications. This unit mount MCCB installs into GE Spectra panelboards and switchboards. It requires an interchangeable rating plug to establish the continuous current rating. Rated 100kAIC at 480V, it features a solid-state electronic trip unit with adjustable LSI functions and true RMS sensing.

Specifications

Key specifications
Brand ABB / General Electric
Series SGPA
Amperage 400A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 200kA @ 240VAC, 100kA @ 480VAC, 65kA @ 600VAC
Fit and installation
Terminal Type Lugs
For Use With GE Spectra Panelboards, Switchboards
Wire Gauge (1) 8 AWG - 600 kcmil (Cu/Al) or (2) 2/0 AWG - 500 kcmil (Cu/Al)
Max Wire 600 kcmil (1 conductor) or 500 kcmil (2 conductors)
Min Wire 8 AWG (1 conductor) or 2/0 AWG (2 conductors)
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LSI
Trip Function Long-Time, Short-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator, Lug Kits
Accessories Lugs Not Included
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval CE, CSA, IEC, UL
Temp Rating 40C
Construction Features HACR Rated, Current Limiting, Reverse Feed, True RMS Sensing, Interchangeable Rating Plug

Product FAQs

10 answers
Is the GE Spectra SGPA36AT4400C still in active production?

No. The GE Spectra RMS series has been retired following ABB's acquisition of GE Industrial Solutions. It is officially replaced by the ABB Tmax XT series, specifically the XT5 frame, which requires a retrofit kit for installation into legacy Spectra panelboards.

Does this breaker require a separate rating plug?

Yes. Like all GE Spectra RMS breakers, the SGPA36AT4400C requires a front-mounted rating plug (SRPG series) to establish the specific operational amperage, even if you intend to use it at the maximum 400A frame rating.

What does the C suffix in the SGPA36AT4400C catalog number indicate?

The C at the end of the catalog number indicates that the breaker comes with standard factory-installed line and load lugs.

What adjustments does the LSI electronic trip unit provide?

The solid-state LSI trip unit allows precise coordination by letting you adjust the Long-Time (overload), Short-Time (short circuit with intentional delay), and Instantaneous (immediate short circuit) trip functions.

Which panelboards are compatible with the SGPA36AT4400C?

This SG-frame breaker is designed for bolt-on installation in legacy GE Spectra Series power panelboards, switchboards, and motor control centers.

Can this breaker be reverse fed?

Yes. GE Spectra RMS molded case circuit breakers do not have line and load restrictions and can be reverse fed safely.

What does the True RMS Sensing feature do on this breaker?

True RMS sensing allows the electronic trip unit to accurately measure and respond to both sinusoidal and non-sinusoidal currents, preventing nuisance tripping from harmonic loads like variable frequency drives or discharge lighting.

How is the SGPA36AT4400C mounted into the panelboard?

This is a unit-mount, bolt-on circuit breaker. It bolts directly to the busbars in compatible GE Spectra panelboards and switchboards using the appropriate mounting hardware kit.

Is this circuit breaker HACR rated?

Yes. The SGPA36AT4400C is HACR rated, meaning it is approved for use with heating, air conditioning, and refrigeration equipment.

Why choose the SGPA frame over the SGLA frame?

The SGPA frame provides a higher short-circuit interrupting capacity. It is rated for 100kAIC at 480VAC, whereas the standard SGLA frame is rated for 65kAIC at 480VAC.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.