ABB / General ElectricTHFK236175
Quantity
Re-Certified
Quantity
ABB / General ElectricTHFK236175
ABB / General ElectricTHFK236150
ABB / General ElectricTHFK236125
ABB / General ElectricTHFK236070
| Brand | ABB / General Electric |
|---|---|
| Part Number | THFK236200-R |
| Series | THFK |
| Amperage | 200A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Frame Type | TFK |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs (TCAL24) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip, High Interrupting Capacity |
This F-frame breaker is designed for use in GE A-Series panelboards, switchboards, and motor control centers.
This breaker utilizes a bolt-on connection type, requiring it to be physically bolted to the busbar of compatible GE A-Series panelboards or switchboards.
The standard lugs accept copper or aluminum conductors ranging from 4 AWG to 300 kcmil.
The H designates this as a high-interrupting capacity version of the standard TFK breaker, providing a 25kAIC rating at 480VAC.
Yes, the THFK series features an interchangeable thermal-magnetic trip unit, unlike the TFJ series which has a non-interchangeable trip.
It includes a thermal-magnetic trip unit with fixed thermal and adjustable magnetic settings, providing long-time and instantaneous (LI) protection.
Yes, this breaker is rated for up to 250VDC with an interrupting capacity of 10kAIC.
In GE nomenclature, a WL suffix indicates the breaker includes factory-installed copper and aluminum line and load lugs. The standard THFK236200 provided here already includes these lugs.
No, this is a standard thermal-magnetic breaker providing only long-time and instantaneous (LI) overcurrent and short-circuit protection. It does not include ground fault or equipment protection features.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.