ABB / General ElectricTHKMA31000WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THKMA312000WL |
| Series | THKMA |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC, 40kA @ 250VDC, 22kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (4) 250-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 250 kcmil |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs (TCAL121) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip, High Interrupting Capacity |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THKMA312000WL-R |
| Series | THKMA |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC, 40kA @ 250VDC, 22kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (4) 250-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 250 kcmil |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs (TCAL121) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip, High Interrupting Capacity |
ABB / General ElectricTHKMA31000WL
ABB / General ElectricTHKMA836800WL
ABB / General ElectricTHKMA836600WL
ABB / General ElectricTHKMA836500WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THKMA312000WL |
| Series | THKMA |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC, 40kA @ 250VDC, 22kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (4) 250-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 250 kcmil |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs (TCAL121) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip, High Interrupting Capacity |
This 1200A K-frame breaker is designed for unit-mount or bolt-on installation in legacy GE A-Series panelboards, switchboards, and motor control centers.
While the thermal (long-time) trip is fixed at 1200A, the magnetic (instantaneous) trip is adjustable. Electricians can set the short-circuit trip threshold anywhere from 3600A to 10000A using the front dial to ensure proper selective coordination with downstream devices.
The factory-installed lugs accommodate four 250 to 500 kcmil copper or aluminum conductors per phase. Ensure proper torque specifications are followed during installation to prevent thermal issues.
ABB acquired GE Industrial Solutions in 2018. Legacy GE molded case circuit breakers, including the K-frame THKMA series, are now manufactured and supported by ABB while maintaining exact backward compatibility with existing GE installations.
The WL designation signifies that the breaker is supplied with factory-installed line and load lugs. Breakers without this suffix typically require terminal lugs to be purchased and installed separately.
When applying this breaker in direct current systems up to 500VDC, ensure the available system fault current does not exceed its 22kA DC interrupting rating. Proper pole wiring configurations must be followed for safe DC isolation.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.