ABB / General ElectricTHKMA836500WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THKMA836600WL |
| Series | THKMA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC, 40kA @ 250VDC, 22kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (3) 3/0 AWG-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Interchangeable Trip Unit |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THKMA836600WL-R |
| Series | THKMA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC, 40kA @ 250VDC, 22kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (3) 3/0 AWG-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Interchangeable Trip Unit |
ABB / General ElectricTHKMA836500WL
ABB / General ElectricTHKMA836800WL
ABB / General ElectricTHKMA31000WL
ABB / General ElectricTHKMA312000WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THKMA836600WL-R |
| Series | THKMA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC, 40kA @ 250VDC, 22kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (3) 3/0 AWG-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Interchangeable Trip Unit |
This 600A K-frame breaker is designed for use in GE A-Series panelboards, switchboards, and motor control centers. It utilizes a unit mount, feed-thru connection.
The factory-installed lugs accept three 3/0 AWG to 500 kcmil copper or aluminum conductors per phase. Ensure proper torque specifications are followed during installation as outlined by the manufacturer.
It features a thermal-magnetic trip unit with fixed thermal and adjustable magnetic settings. This allows you to adjust the instantaneous short-circuit pickup level to coordinate with other protective devices, while the long-time overload protection remains fixed at 600 amps.
In GE circuit breaker nomenclature, the WL suffix indicates that the breaker is supplied with factory-installed line and load lugs.
Installation must be performed by a qualified electrician. Always de-energize the panelboard or switchboard before installation, verify power is off using a properly rated voltage sensing device, and wear appropriate arc flash PPE in accordance with NFPA 70E guidelines.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.