Part of the legacy Murray family, the MPP2150 is a 150A main circuit breaker providing essential thermal-magnetic protection. It operates on standard 120/240V AC residential systems and features a common trip mechanism. This plug-on breaker requires four panel spaces and installs into older Murray and Siemens load centers. It is officially replaced by the QN2150, making it an ideal cross-reference for exact panel matching. Rated at 10 kAIC, it meets UL 489 standards for safe residential use.
No. Siemens has phased out the Murray brand name and discontinued the MPP series. The direct, UL listed replacements for the MPP2150 are the Siemens QPP2150 or QN2150, depending on your specific panel configuration.
Can I install the MPP2150 in a Siemens load center?
Yes. Because Siemens acquired Murray, the MPP2150 is compatible with and UL listed for use in both Murray and Siemens load centers that accept MPP or QN frame breakers.
How many panel spaces does the MPP2150 require?
This breaker requires four full-size panel spaces (two adjacent spaces and two opposite spaces) within the load center.
Can the MPP2150 be used as a branch breaker?
Yes. While commonly used as a main breaker, it can also be installed as a branch breaker in compatible load centers, provided the panel busbar is rated to accept a 150A plug-in breaker and has the required four spaces available.
Does the MPP2150 require a hold-down kit?
If installed as a back-fed main breaker, the National Electrical Code (NEC) requires a hold-down kit to secure the breaker to the busbar. If installed in a dedicated main breaker position with a factory retainer, an additional kit may not be needed.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.