Engineered to save enclosure space, this quadplex breaker provides two independent 40A, 240V circuits while only occupying two standard pole positions. It is ideal for residential environments requiring multiple high-draw feeds. The plug-on module installs easily into compatible Murray load centers. For modern upgrades, this specific model transitions to the newer Siemens Q24040CT2 substitute. Both the center and outer poles feature common trip mechanisms, supported by a 10kAIC rating.
Which load centers are approved for the MP240240CT2 circuit breaker?
This breaker is UL listed for use in Murray load centers that accept MP-T or MH-T type plug-in breakers. It is commonly used to add 240V circuits to older Murray panels where space is limited.
How many panel spaces does this quadplex breaker occupy?
It requires two standard 1-inch panel spaces. This quadplex design allows you to install two independent 2-pole 40A circuits in the physical footprint normally required for a single 2-pole breaker.
How are the 40A circuits configured on this quad breaker?
The breaker contains two separate 40A, 240V circuits. The two outer poles are tied together to form the first 2-pole 40A circuit, while the two inner poles form the second 2-pole 40A circuit.
Are the inner and outer circuits common trip?
Yes, the CT2 designation indicates that both the inner 40A circuit and the outer 40A circuit feature an internal common trip. An overload on one leg of a circuit will trip both poles of that specific circuit to safely disconnect 240V power.
Is this breaker a direct replacement for older Murray 40/40 quad breakers?
Yes, the Siemens MP240240CT2 is the exact manufacturer replacement for legacy Murray MP240240CT2 breakers. Siemens acquired Murray and continues to produce the MP line to support existing Murray load centers.
What type of loads is this 40/40A quad breaker typically used for?
With two independent 40A 240V circuits, it is frequently used to supply power to heavy residential loads such as electric ranges, large air conditioning condensers, or subpanels, provided the panel bus has sufficient capacity.
What are the best practices for terminating aluminum wire on this breaker?
While the lugs accept 8 to 4 AWG aluminum conductors, you should apply a listed joint compound to the stripped aluminum wire before insertion. Torque the terminal screws to the manufacturer specifications printed on the breaker to prevent thermal expansion issues.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 4 reviews.
Thank you so much for sending me a 100 amp breaker that was in the condition that you said it would be in.With out your breaker I would still be in the dark Thank you David