Siemens NGG3B100L Molded Case Circuit Breaker

  • 100A
  • 3 Pole
  • Unit Mount
Siemens NGG3B100L
Molded Case Circuit Breaker
Brand Siemens
SKU NGG3B100L
Select Item Condition
Earn 841 SuperPoints
  • 100A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Siemens NGG3B100L - 100A 3 Pole Molded Case Circuit Breaker

Siemens NGG3B100L - 100A 3 Pole Molded Case Circuit Breaker

New

$841.00 In Stock

Quantity

Similar Items

Description

Serving as a critical component in industrial power distribution, this 100A Sentron breaker utilizes proven thermal-magnetic trip technology. It fastens securely into Siemens P1, P2, and P3 panelboards, while also accommodating DIN rail mounting for control panel flexibility. Delivering 25kAIC at 480VAC, the reverse-feed capable unit handles complex routing. While superseded by the 3VA5110-4ED36-0AA0, this exact match remains essential for servicing existing GB/GG frame installations.

Specifications

Key specifications
Brand Siemens
Series NGG
Amperage 100A
Poles 3
Mounting Style Unit Mount
Voltage 120VAC, 240VAC, 480VAC, 600Y/347VAC, 125/250VDC
Phase 3
AIC Rating 100kA @ 120VAC, 65kA @ 240VAC, 25kA @ 480VAC, 14kA @ 600Y/347VAC, 14kA @ 125/250VDC
Fit and installation
Frame Type NGG
Terminal Type Lugs
For Use With DIN Rail Enclosures, Control Panels, Switchboards
Wire Gauge 8-1/0 AWG (Cu), 8-2/0 AWG (Al)
Max Wire 1/0 AWG (Cu), 2/0 AWG (Al)
Min Wire 8 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment
Accessories Line & Load Side Lugs (3TC1GG20)
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval CE, CSA, HACR, NOM, UL
Temp Rating 40C

Product FAQs

8 answers
Does the NGG3B100L require an adapter bracket for DIN rail mounting?

No, the Siemens NGG frame is designed with an integral mounting channel that allows it to snap directly onto a standard DIN rail. It can also be secured to a base plate with standard mounting screws without requiring extra adapters.

What does the L suffix in the NGG3B100L catalog number mean?

The L indicates that this specific model comes from the factory with line and load-side wire lugs included. If you are sourcing a version that requires custom terminations, the L is omitted from the base catalog number.

Is the Siemens NGG3B100L approved for reverse feed applications?

Yes, because it is built with a non-interchangeable thermal-magnetic trip unit, this breaker is UL listed for reverse feed applications.

Can I install this NGG frame breaker directly onto a standard Siemens panelboard bus?

The NGG frame is specifically designed for unit mounting in DIN rail enclosures, control panels, or switchboards. For plug-on or bolt-on installation within a typical Siemens lighting panelboard, the NGB frame equivalent (such as NGB3B100L) is usually required instead.

How should I wire this 3-pole breaker if I am using it in a 250VDC system?

When applying this molded case circuit breaker on a 250 VDC system, Siemens application guidelines require placing one pole on each leg of the DC supply circuit.

Are there any specific ambient temperature requirements for this breaker?

The NGG frame is factory calibrated for a 40 degrees C (104 degrees F) ambient operating temperature. It is designed for enclosed spaces free of corrosive vapors or heavy dust. For installations outdoors or in damp environments, it must be housed in a suitably rated protective enclosure.

Will the breaker still trip if the handle is physically held in the ON position?

Yes. The NGG frame features a trip-free overcenter toggle mechanism. If a short circuit or overload condition occurs, the internal contacts are forced apart and the breaker will trip even if the handle is physically restrained.

Is the NGG3B100L suitable for HVAC equipment protection?

Yes, this circuit breaker is HACR rated, meaning it is safety certified for use with commercial heating, air conditioning, and refrigeration equipment.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.