Built to handle higher fault currents, this 22kAIC-rated ground-fault interrupter delivers 5mA personnel safety for demanding environments. The unit installs into Siemens, Murray, PL, and ES series load centers using a traditional pigtail neutral wire. Featuring common trip functionality and self-testing diagnostics, it satisfies strict NEC requirements for commercial and residential wet locations.
Can I install the Q220GFH in a Murray load center?
Yes, this breaker is fully compatible with Murray load centers, as well as Siemens PL, ES, EQ, and Ultimate panels.
What is the difference between the Siemens Q220GF and the Q220GFH?
The Q220GFH features a higher interrupting rating of 22kAIC, whereas the standard Q220GF is rated for 10kAIC. Both provide 20A, 2-pole ground fault protection.
What does the H in the Q220GFH catalog number signify?
The H indicates that this is a high-interrupting breaker, rated for 22kAIC at 240V, compared to the standard 10kAIC rating of the base Q220GF model.
Does this breaker require a pigtail neutral connection?
Yes, the Q220GFH is equipped with a pigtail neutral wire that must be connected to the panel neutral bar for the ground fault protection to function properly.
Can I use this 2-pole GFCI breaker on a circuit without a load neutral?
Yes, a load neutral is not required on the circuit for straight 240V applications. However, the breaker's white pigtail wire must still be connected to the panel neutral for the GFCI sensor to operate.
What class of ground fault protection does the Q220GFH provide?
It provides Class A ground fault protection, which is designed to trip when a current imbalance of 4 to 6 milliamps is detected to protect personnel from electrical shock.
Does this breaker provide arc fault (AFCI) protection?
No, the Q220GFH is strictly a Ground Fault Circuit Interrupter (GFCI). It does not provide dual-function AFCI/GFCI protection.
What older Siemens breaker does the Q220GFH replace?
The Q220GFH is the direct replacement for the older Siemens QF220H model, providing the same 20A, 2-pole ground fault protection with a 22kAIC rating.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.