Serving as a critical service entrance component, this 200-amp main breaker handles substantial electrical loads. It offers dependable thermal-magnetic trip functionality for modern commercial and residential metering applications. Integration is seamless with Siemens Uni-PAK, Power Mod meter stacks, and standard load centers. The plug-on configuration allows for efficient integration into existing enclosures.
Siemens Power Mod Meter Stacks, Siemens Uni-PAK, Siemens WMM Series, Siemens Load Centers
Wire Gauge
3 AWG - 300 kcmil (Cu/Al)
Max Wire
300 kcmil
Min Wire
3 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed
Standards and features
Available Options
Padlock Attachment
Accessories
Load Side Lugs Included
Standards
CSA C22.2 No. 5, UL 489
Approval
CSA, UL
Temp Rating
40°C
Construction Features
HACR Rated, High Interrupting Capacity, Main Breaker, Common Trip
Product FAQs
8 answers
What equipment is the Siemens QSH2200 designed to be installed in?
This breaker is designed for use as a tenant main breaker in Siemens Power Mod meter stacks, including WMM, WML, and WMT series, as well as Siemens Uni-PAK metering enclosures.
Can I use the QSH2200 as a branch breaker in a standard Siemens load center?
No. The QSH2200 is a specialized QS frame main breaker designed specifically for Siemens multifamily metering equipment. It does not fit standard residential load centers that require QP or QN frame breakers.
What is the difference between the Siemens QS2200 and the QSH2200?
The difference is the short circuit interrupting rating. The standard QS2200 is rated at 10kAIC, while the QSH2200 has a higher interrupting rating of 42kAIC at 120/240VAC.
Are there versions of this 200A QS breaker with higher interrupting ratings?
Yes. If your system requires a higher fault current rating, you can use the QS2200HH, which is rated for 65kAIC, or the HQS2200H, which is rated for 100kAIC.
What is the required tightening torque for the wire lugs on the QSH2200?
The terminal lugs should be torqued to 250 lb-in for both copper and aluminum conductors ranging from 3 AWG to 300 kcmil.
Does the QSH2200 require difficult wire bending during installation?
No. The QS frame features an exclusive side wired design that allows for a single right hand bend. This eliminates the need for difficult S bends, saving wiring space and installation time in the meter stack.
What is the direct 10kAIC equivalent to the QSH2200?
The standard 10kAIC version of this 200A, 2-pole breaker is catalog number QS2200.
What is the 22kAIC equivalent to the QSH2200?
The 22kAIC version of this 200A, 2-pole breaker is catalog number QS2200H.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.