Siemens B115AFC AFCI Molded Case Circuit Breaker

  • 15A
  • 1 Pole
  • Bolt-On
Siemens B115AFC
AFCI Molded Case Circuit Breaker
Brand Siemens
SKU B115AFC
Select Item Condition
Earn 205 SuperPoints
  • 15A
  • 1 Pole
  • Bolt-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Siemens B115AFC - 15A AFCI Molded Case Circuit Breaker

New

$205.65 In Stock

Quantity

Description

Rated at 10 kAIC, this 15-amp combination arc-fault circuit breaker delivers advanced protection against dangerous arcing conditions. The Siemens B115AFC features a bolt-on mounting design, making it a secure fit for commercial and industrial applications. It installs into Siemens P1, P2, P3, P4, and P5 panelboards. Serving as a direct upgrade, this unit replaces the older B115AF branch/feeder model to meet modern NEC combination AFCI requirements. Includes a pigtail neutral and SWD rating.

Specifications

Key specifications
Brand Siemens
Series B
Amperage 15A
Poles 1
Mounting Style Bolt-On
Voltage 120VAC
Phase 1
AIC Rating 10kA @ 120VAC
Fit and installation
Terminal Type Lugs
For Use With Siemens P1, P2, P3, P4, P5 Panelboards
Wire Gauge 14-10 AWG (Cu), 12-10 AWG (Al)
Max Wire 10 AWG
Min Wire 14 AWG (Cu), 12 AWG (Al)
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Special Classification AFCI
Available Options Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment
Accessories Pigtail Neutral
Standards CSA C22.2 No. 5, UL 1699, UL 489
Approval CSA, HACR, SWD, UL
Temp Rating 40C
Construction Features HACR Rated, SWD Rated

Product FAQs

7 answers
Which panelboards are compatible with the B115AFC breaker?

This bolt-on breaker is engineered specifically for Siemens P1, P2, P3, P4, and P5 commercial panelboards. It will not fit in standard residential plug-on load centers.

Can I use the B115AFC to replace a B115AF breaker?

Yes. The B115AFC is a combination arc fault circuit interrupter that serves as a direct, code-compliant upgrade for the older B115AF branch/feeder model, meeting current NEC standards for arc fault protection.

Does this breaker require a plug-on neutral panel?

No, the B115AFC is equipped with a pigtail neutral wire. This pigtail must be routed and secured to the neutral bus bar in the panelboard for the arc fault circuitry to function correctly.

Is the B115AFC suitable for multi-wire branch circuits?

No. Because this is a single-pole 120V arc fault breaker with a pigtail neutral, it cannot be used on shared-neutral multi-wire branch circuits. Each AFCI breaker requires a dedicated neutral for the circuit it protects.

What wire sizes are accepted by the load terminals on the B115AFC?

The load lugs accommodate 14 to 10 AWG copper or 12 to 10 AWG aluminum conductors. Always verify the required torque settings printed on the breaker face before terminating the wire.

What is the difference between this combination AFCI and a standard breaker?

While standard breakers only trip during overloads or short circuits, this combination AFCI actively monitors the circuit for dangerous parallel and series arcing conditions to prevent electrical fires.

What do the long-time and instantaneous trip functions indicate?

The long-time function provides thermal protection against sustained overloads, while the instantaneous magnetic function trips the breaker immediately during a severe short circuit.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.