Rated for 65kAIC at 120V, the Siemens QA115AFCHH provides extra-high interrupting capacity for demanding residential applications. This 15-amp combination arc-fault circuit breaker features a standard pigtail neutral and thermal-magnetic trip technology to protect against series and parallel arcing. It mounts into Siemens EQ, EQL, SEQ, EQG, PL, ES, and Ultimate load centers. Built with Insta-Wire connectors and LED trip indicators, it ensures fast installation and easy troubleshooting.
Combination Arc Fault, Parallel Arc Fault, Series Arc Fault, HACR Rated, SWD Rated, Visual Trip Indicator, Extra High Interrupting Capacity, Insta-Wire
Product FAQs
7 answers
Which load centers are compatible with the QA115AFCHH circuit breaker?
This breaker is designed for use in Siemens EQ, EQL, SEQ, EQG, PL, ES, and Ultimate load centers.
Does the QA115AFCHH require a plug-on neutral load center?
No. This breaker features a standard pigtail neutral. The attached coiled white wire connects directly to the panel's neutral bus bar, allowing installation in standard load centers that lack a plug-on neutral design.
What wire sizes are accepted by the lugs on this 15A AFCI breaker?
The terminal lugs accept 14 to 8 AWG copper wire or 12 to 8 AWG aluminum wire.
What type of arc fault protection does the QA115AFCHH provide?
As a combination AFCI, it detects and mitigates both series and parallel arcing faults. This provides more comprehensive protection against electrical fires than older branch-feeder AFCI models.
What does the HH suffix in the QA115AFCHH part number indicate?
The HH suffix designates an extra-high interrupting rating of 65kAIC at 120V. This makes the breaker suitable for applications with high available fault currents, such as installations located very close to a utility transformer.
Can the QA115AFCHH replace a standard 15A Siemens QP breaker?
Yes, it fits the same 1-inch space as a standard Siemens QP breaker. It is commonly used to upgrade standard circuits to meet modern electrical codes requiring arc fault protection, provided there is space to land the pigtail on the neutral bus.
How does the thermal-magnetic trip function work on this AFCI breaker?
The QA115AFCHH combines electronic arc fault detection with traditional thermal-magnetic mechanisms. The thermal element provides a long-time delay for standard overloads, while the magnetic element offers an instantaneous trip response for severe short circuits.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.