Skip to main content
Expedited shipping available at checkout

Siemens 3VA4125-6ED34-0AA0 Molded Case Circuit Breaker

  • 25A
  • 3 Pole
  • Panel Mount
Siemens 3VA4125-6ED34-0AA0
Molded Case Circuit Breaker
Brand Siemens
SKU 3VA4125-6ED34-0AA0
Select Item Condition
Earn 473 SuperPoints
  • 25A
  • 3 Pole
  • Panel Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Siemens 3VA4125-6ED34-0AA0 - 25A 3 Pole Molded Case Circuit Breaker

Siemens 3VA4125-6ED34-0AA0 - 25A 3 Pole Molded Case Circuit Breaker

New

$473.20 In Stock

Quantity

Description

Siemens 3VA4125-6ED34-0AA0 molded case circuit breaker is a 25A, 3-pole, 3-phase SENTRON 3VA4 breaker with a 3VA frame and standard protection. Voltage ratings are 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC and 250VDC, with interrupting ratings of 25kAIC at 600Y/347VAC and 65kAIC at 480Y/277VAC. The thermal magnetic trip has LI function and fixed thermal and fixed magnetic settings. It has panelboard or switchboard mounting, a load side lug terminal connection, current limiting, reverse feed, and HACR and HID ratings. Approvals are CE, CSA and UL. Dimensions are 5.09 in high, 3.0 in wide and 2.96 in deep.

Specifications

Key specifications
Brand Siemens
Part Number 3VA4125-6ED34-0AA0
Series 3VA4
Amperage 25A
Poles 3
Mounting Style Panel Mount
Voltage 240VAC, 480VAC, 480Y/277VAC, 600Y/347VAC, 250VDC
Phase 3
AIC Rating 100kA @ 240VAC, 65kA @ 480Y/277VAC, 25kA @ 600Y/347VAC, 100kA @ 250VDC
Fit and installation
Frame Type 3VA41
Terminal Type Lugs
For Use With Siemens P1, P2, P3, P4, P5 Panelboards, Switchboards
Wire Gauge 14-8 AWG (Cu), 12-8 AWG (Al)
Max Wire 8 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch
Accessories Load Side Lugs Included
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval CE, CSA, UL
Temp Rating -25C to 70C
Construction Features HACR Rated, Current Limiting, Reverse Feed, HID Rated

Product FAQs

10 answers
Which system voltages can I select this breaker for?

Its rated voltages are 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC and 250VDC. Match the circuit's voltage and AC or DC system type to the applicable rating; the Y ratings apply to wye systems.

How do I check the interrupting rating against available fault current?

The interrupting ratings are 65kAIC at 480Y/277VAC and 25kAIC at 600Y/347VAC. Select the rating applicable to the system voltage and ensure it meets or exceeds the available fault current at the installation point.

How does the thermal-magnetic trip work, and can I adjust it?

The thermal-magnetic LI trip combines long-time overload protection with instantaneous short-circuit protection. Both the thermal and magnetic settings are fixed, so select it for an application that does not require adjustable trip settings.

What conductor sizes can I terminate at the load-side lug?

The conductor range is 14-8 AWG for copper and 12-8 AWG for aluminum. Select conductors within the range for their material while also meeting the circuit's ampacity requirements.

Can this breaker be reverse-fed?

Yes, it has a reverse-feed feature, allowing the power source to connect in the reverse direction through the breaker. This supports installations that require reverse feeding.

What does the current-limiting feature mean for circuit protection?

Current limiting reduces the peak fault current and energy let through during faults in the breaker's current-limiting operating region. Consider this feature when evaluating fault-energy exposure in the circuit.

Can I use this breaker where HVAC equipment requires HACR-rated protection?

Yes, this breaker is HACR rated for heating, air-conditioning and refrigeration applications. Use that rating when the equipment requires HACR-rated circuit protection.

Why does the HID rating matter when selecting a lighting breaker?

The HID rating addresses the switching demands of high-intensity discharge lighting loads. Use it as a selection criterion when the lighting application requires an HID-rated breaker.

What operating temperature range should I use when planning the installation?

The operating temperature range is -25C to 70C. Check the temperature where the breaker will operate against this range when evaluating the installation environment.

How should I use the 25A rating when selecting the Siemens 3VA4125-6ED34-0AA0?

The 25A rated current is a selection point for overcurrent protection. Evaluate it against the circuit's calculated load, conductor ampacity and applicable sizing requirements.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

5.0
Rated 5.0 out of 5 stars
Based on 5 reviews
Rating
Ratings
5 reviews
  • SW
    SHELDON W.
    Verified Buyer
    Reviewing
    Siemens 3VA4160-4ED34-0AA0 - 60A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    7/27/26
    SuperBreakers has you covered

    SuperBreakers has you covered when you’re in a pinch and need breakers at the last minute. Their customer service is excellent, and the team consistently goes above and beyond to help. I highly recommend them!

  • RS
    Rob S.
    Verified Buyer
    Reviewing
    Siemens 3VA4150-6ED34-0AA0 - 50A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    4/8/26
    50 amp breaker

    Very helpful and arrived quickly.

  • JB
    Josh B.
    Verified Buyer
    Reviewing
    Siemens 3VA4130-4ED24-0AA0 - 30A 2 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    3/5/26
    Breakers

    Exactly as described. Quick shipping.

  • JL
    Jeff L.
    Verified Buyer
    Reviewing
    Siemens 3VA4120-6ED14-0AA0 - 20A 1 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    2/11/26
    Better than new

    Great condition and fast shipping

  • KC
    Ken C.
    Verified Buyer
    Reviewing
    Siemens 3VA4150-4ED34-0AA0 - 50A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    9/22/25
    Breaker Order

    Good prices and fast shipping.