Siemens 3VA4190-5ED34-0AA0 molded case circuit breaker is rated 90A with 3 poles and 3-phase operation. Rated voltages are 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC and 250VDC. Interrupting ratings are 18kAIC at 600Y/347VAC and 35kAIC at 480Y/277VAC. It has a thermal magnetic LI trip with fixed thermal and fixed magnetic settings, standard protection and a 3VA frame. Mounting is for panelboards and switchboards, with a load side lug terminal connection and an 8 AWG - 3/0 AWG conductor range (Cu/Al). Construction features include HACR rated, current limiting and reverse feed. Approvals are CE, CSA, NOM and UL; standards are CSA C22.2 No. 5, IEC 60947-2 and UL 489. Height is 5.09 in, width is 3.0 in and depth is 2.96 in.
How does the Siemens 3VA4190-5ED34-0AA0 protect a 90A circuit?
This 90A breaker uses thermal-magnetic LI protection: thermal operation responds to sustained overloads, and instantaneous magnetic operation responds to short circuits. Both thermal and magnetic settings are fixed, so select it for a circuit that calls for these nonadjustable protection characteristics.
Which system voltages can I use this breaker on?
Rated voltages are 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC and 250VDC. Match the rating to both the system voltage and AC or DC operation; the Y ratings apply to the corresponding wye-system voltages.
How do I check the interrupting rating against available fault current?
The interrupting rating is 35kAIC at 480Y/277VAC and 18kAIC at 600Y/347VAC. At the applicable voltage, select the breaker only when available fault current at the installation point does not exceed that interrupting rating.
What conductors can I terminate at the load-side lug?
The load-side lug accepts copper or aluminum conductors from 8 AWG through 3/0 AWG. Choose a conductor within that range while also meeting the circuit's ampacity requirements; terminal capacity alone does not determine conductor sizing.
Can I feed power into the side normally used for the load?
Yes. Reverse-feed construction permits the incoming supply to connect to the side normally used for the load, giving you flexibility when planning supply routing.
What does current-limiting construction mean for fault protection?
Current-limiting operation restricts fault-current let-through during interruption, reducing the electrical and thermal stress of a short circuit. Use this feature alongside the voltage-specific interrupting rating when evaluating fault protection.
What does the HACR rating mean for equipment applications?
HACR means heating, air-conditioning and refrigeration. The HACR rating supports selecting this breaker for those applications when its current, voltage and interrupting ratings meet the circuit requirements.
What dimensions should I use when planning the installation layout?
The breaker is 5.09 in high, 3.0 in wide and 2.96 in deep. Use these dimensions to plan the space occupied by the breaker, while accounting separately for conductor routing and termination access.
What operating temperature range should I account for?
The operating temperature range is -25C to 70C. Evaluate the temperature at the breaker location, including enclosure conditions, when selecting the installation environment.
Which circuit breaker standards apply to this model?
This molded case circuit breaker carries UL, CSA, CE and NOM approvals, with standards including UL 489, CSA C22.2 No. 5 and IEC 60947-2. Use these credentials when checking the approval and circuit breaker standard requirements for your project.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 5 reviews.
Siemens 3VA4160-4ED34-0AA0 - 60A 3 Pole Molded Case Circuit Breaker
I recommend this product
Rated 5 out of 5 stars
7/27/26
SuperBreakers has you covered
SuperBreakers has you covered when you’re in a pinch and need breakers at the last minute. Their customer service is excellent, and the team consistently goes above and beyond to help. I highly recommend them!
RS
Rob S.
Verified Buyer
Reviewing
Siemens 3VA4150-6ED34-0AA0 - 50A 3 Pole Molded Case Circuit Breaker
I recommend this product
Rated 5 out of 5 stars
4/8/26
50 amp breaker
Very helpful and arrived quickly.
JB
Josh B.
Verified Buyer
Reviewing
Siemens 3VA4130-4ED24-0AA0 - 30A 2 Pole Molded Case Circuit Breaker
I recommend this product
Rated 5 out of 5 stars
3/5/26
Breakers
Exactly as described. Quick shipping.
JL
Jeff L.
Verified Buyer
Reviewing
Siemens 3VA4120-6ED14-0AA0 - 20A 1 Pole Molded Case Circuit Breaker
I recommend this product
Rated 5 out of 5 stars
2/11/26
Better than new
Great condition and fast shipping
KC
Ken C.
Verified Buyer
Reviewing
Siemens 3VA4150-4ED34-0AA0 - 50A 3 Pole Molded Case Circuit Breaker