Siemens 3VA4195-5ED34-0AA0 Molded Case Circuit Breaker

  • 15A
  • 3 Pole
  • Bolt-On
Siemens 3VA4195-5ED34-0AA0
Molded Case Circuit Breaker
Brand Siemens
SKU 3VA4195-5ED34-0AA0
Select Item Condition
Earn 401 SuperPoints
  • 15A
  • 3 Pole
  • Bolt-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Siemens 3VA4195-5ED34-0AA0 - 15A 3 Pole Molded Case Circuit Breaker

Siemens 3VA4195-5ED34-0AA0 - 15A 3 Pole Molded Case Circuit Breaker

New

$401.80 In Stock

Quantity

Description

Siemens 3VA4195-5ED34-0AA0 is a 15A, 3-pole, 3-phase molded case circuit breaker rated for 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC and 250VDC. Interrupting ratings are 18kAIC at 600Y/347VAC and 35kAIC at 480Y/277VAC. The thermal magnetic trip has fixed thermal and fixed magnetic settings with long-time and instantaneous functions. This SENTRON 3VA4 series breaker has a 3VA frame, standard protection, panelboard and switchboard mounting, and a load side lug terminal connection. Construction features include HACR rated and reverse feed. It has CE, CSA, NOM and UL approvals, with standards CSA C22.2 No. 5, IEC 60947-2 and UL 489. Dimensions are 5.09 in high, 3 in wide and 2.96 in deep. The conductor range is 14 AWG - 8 AWG (Cu/Al), and operating temperature is -25C to 70C. Country of origin is Mexico.

Specifications

Key specifications
Brand Siemens
Part Number 3VA4195-5ED34-0AA0
Series 3VA4
Amperage 15A
Poles 3
Mounting Style Bolt-On
Voltage 240VAC, 480VAC, 480Y/277VAC, 600Y/347VAC, 250VDC
Phase 3
AIC Rating 85kA @ 240VAC, 35kA @ 480Y/277VAC, 35kA @ 480VAC, 18kA @ 600Y/347VAC, 85kA @ 250VDC
Fit and installation
Frame Type 3VA41
Terminal Type Lugs
For Use With Siemens P1 Panelboards, Siemens P2 Panelboards, Siemens P3 Panelboards
Wire Gauge 14-8 AWG (Cu/Al)
Max Wire 8 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release
Accessories Load Side Lugs
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval CE, CSA, NOM, UL
Temp Rating -25C to 70C
Construction Features HACR Rated, Reverse Feed

Product FAQs

10 answers
How does the 15A thermal-magnetic trip affect circuit protection?

The Siemens 3VA4195-5ED34-0AA0 has a 15A rating with fixed thermal and fixed magnetic trips. The thermal function handles sustained overloads, while the instantaneous magnetic function responds to short circuits. Select it where the circuit design calls for 15A protection without trip adjustment.

How do I select the breaker for the available fault current?

The interrupting ratings are 35kAIC at 480Y/277VAC and 18kAIC at 600Y/347VAC. At the applicable system voltage, select an interrupting rating equal to or greater than the available fault current at the installation point.

Which system voltages can I select this breaker for?

The voltage ratings are 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC and 250VDC. Match both voltage and system configuration when selecting the breaker. The Y ratings apply to grounded-wye systems.

What conductors can I terminate at the load-side lugs?

The conductor range is 14 AWG through 8 AWG for copper or aluminum, with load-side lug connections. Choose a conductor within that range that also meets the circuit's ampacity requirements.

Can I reverse-feed this breaker?

Yes, this breaker has a reverse-feed feature, allowing the incoming supply to enter through the load-side terminals. This supports circuit layouts that require the supply direction to be reversed.

What does the HACR rating mean for equipment selection?

The HACR rating covers use in heating, air-conditioning and refrigeration applications. Use it when the equipment's electrical requirements call for an HACR-rated breaker, while also matching the required current and voltage ratings.

What operating temperature range should I use when planning the installation?

The operating temperature range is -25C to 70C. Use this range when evaluating the temperatures the breaker will encounter in service.

How much space should I allow for the breaker body?

The breaker measures 5.09 in high, 3 in wide and 2.96 in deep. Use these body dimensions for layout planning, with separate allowance for conductor routing and termination access.

Which breaker standards are relevant when reviewing project requirements?

The breaker standards are UL 489, CSA C22.2 No. 5 and IEC 60947-2. Compare these with the project's required breaker standards when selecting the device.

How does the pole count guide circuit design?

The Siemens 3VA4195-5ED34-0AA0 has three poles and a three-phase rating. Review pole count alongside phase count when planning overcurrent protection for the circuit's phase conductors.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

5.0
Rated 5.0 out of 5 stars
Based on 5 reviews
Rating
Ratings
5 reviews
  • SW
    SHELDON W.
    Verified Buyer
    Reviewing
    Siemens 3VA4160-4ED34-0AA0 - 60A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    7/27/26
    SuperBreakers has you covered

    SuperBreakers has you covered when you’re in a pinch and need breakers at the last minute. Their customer service is excellent, and the team consistently goes above and beyond to help. I highly recommend them!

  • RS
    Rob S.
    Verified Buyer
    Reviewing
    Siemens 3VA4150-6ED34-0AA0 - 50A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    4/8/26
    50 amp breaker

    Very helpful and arrived quickly.

  • JB
    Josh B.
    Verified Buyer
    Reviewing
    Siemens 3VA4130-4ED24-0AA0 - 30A 2 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    3/5/26
    Breakers

    Exactly as described. Quick shipping.

  • JL
    Jeff L.
    Verified Buyer
    Reviewing
    Siemens 3VA4120-6ED14-0AA0 - 20A 1 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    2/11/26
    Better than new

    Great condition and fast shipping

  • KC
    Ken C.
    Verified Buyer
    Reviewing
    Siemens 3VA4150-4ED34-0AA0 - 50A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    9/22/25
    Breaker Order

    Good prices and fast shipping.