Siemens Q34000S01 - 40A 3 Pole Miniature Circuit Breaker

Siemens Q34000S01 - 40A 3 Pole Miniature Circuit Breaker

New

$324.80 In Stock

Quantity

Similar Items

Description

Offering advanced control, the Siemens Q34000S01 is a 40A, 3-pole breaker equipped with a 120VAC shunt trip. This allows users to remotely open the breaker for emergency shutdowns. Designed for commercial applications, this Type QP breaker utilizes a plug-on mounting configuration. It installs securely into compatible Siemens load centers and P1 panelboards. The unit provides thermal-magnetic protection with a 10kAIC rating at 240VAC, features Insta-Wire connections, and is HACR rated.

Specifications

Key specifications
Brand Siemens
Part Number Q34000S01
Series QP
Amperage 40A
Poles 3
Mounting Style Plug-On
Voltage 240VAC
Phase 3
AIC Rating 10kA @ 240VAC
Fit and installation
Terminal Type Lugs
For Use With Siemens Load Centers, Siemens P1 Panelboards
Wire Gauge 8-6 AWG (Cu), 8-4 AWG (Al)
Max Wire 4 AWG
Min Wire 8 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed
Standards and features
Available Options Padlock Attachment
Accessories Shunt Trip (120VAC)
Standards UL 489, CSA C22.2 No. 5
Approval CSA, NOM, UL
Temp Rating 40C
Construction Features Common Trip, HACR Rated

Product FAQs

8 answers
What does the 00S01 suffix indicate on this Siemens breaker?

The 00S01 suffix designates a factory-installed 120V AC shunt trip accessory. This feature allows the breaker to be opened remotely via an external control signal, which is commonly used for emergency stop circuits or automated equipment shutdowns.

Can the Q34000S01 be used in a standard residential load center?

This is a 3-pole breaker designed for 3-phase systems. It requires three adjacent bus stabs and cannot be installed in a standard 120/240V single-phase residential load center. It must be installed in a 3-phase Siemens load center or P1 panelboard.

How is the shunt trip accessory wired on the Q34000S01?

The factory-installed shunt trip includes external pigtail wires that exit the side of the breaker housing. These leads must be connected to a 120V AC control circuit and a momentary normally open switch to activate the remote trip function.

Can the Q34000S01 be applied on systems exceeding 10kA available fault current?

The breaker has a standalone interrupting rating of 10kA at 240V AC. It can only be applied on systems with higher fault currents if it is installed downstream of a fully rated main breaker as part of a UL-listed series combination specified by Siemens.

What are the conductor requirements for the Q34000S01 terminals?

The mechanical lugs are rated for both copper and aluminum conductors. They accept 8 to 6 AWG copper or 8 to 4 AWG aluminum wire. Always torque the terminals to the exact specifications printed on the breaker label to prevent overheating.

Does the Q34000S01 provide personnel ground fault protection?

No. This unit features standard thermal-magnetic trip technology for overload and short-circuit protection. It does not contain GFCI or AFCI circuitry.

Is the Siemens Q34000S01 compatible with older ITE load centers?

Siemens Type QP breakers are the direct modern replacements for older ITE and Gould EQ-P breakers. However, you must verify the wiring diagram inside the specific legacy panel to confirm that Type QP breakers are listed as acceptable.

Does the Q34000S01 require a bolt-on connection?

No. The Q34000S01 is a Type QP breaker, which utilizes a plug-on mounting design. It snaps directly onto the busbar of compatible panels and does not use bolt-on tabs.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.