Built for motor protection, the Siemens 3VA5102-1MU31-0AA0 motor circuit protector is rated 2A at 480VAC and 690VAC. This 3-pole, 3-phase device has a 65kA interrupting rating at 480VAC and a 3VA51 frame. It uses panel mounting, lug terminals and an adjustable magnetic-only trip with instantaneous operation. Standards include IEC 60947-2 and UL 489, with CE, CSA, UL and VDE approvals.
Alarm Switch, Auxiliary Switch, Motor Operator, Shunt Trip, Undervoltage Release
Standards
IEC 60947-2, UL 489
Approval
CE, CSA, UL, VDE
Temp Rating
-25C to 70C
Construction Features
Motor Circuit Protector
Product FAQs
8 answers
What protection does the Siemens 3VA5102-1MU31-0AA0 provide for a motor circuit?
This motor circuit protector uses magnetic-only, instantaneous tripping for short-circuit protection. Coordinate it with motor overload protection so the motor circuit has protection against both short circuits and sustained overloads.
How should I use the 2A rated current when selecting this motor circuit protector?
Use the 2A rated current when evaluating the motor circuit's current requirements. Treat rated current and magnetic pickup as separate selection considerations, because the adjustable magnetic setting controls instantaneous tripping.
Why is adjustable magnetic tripping useful on a motor circuit?
Adjustable magnetic tripping lets you coordinate instantaneous pickup with motor-starting inrush and short-circuit protection requirements. Select the setting as part of the motor circuit's protection coordination.
How do the voltage and interrupting ratings guide selection?
The voltage ratings are 480VAC and 690VAC. At 480VAC, the 65kA interrupting rating must meet or exceed the available fault current at the installation point.
How does the three-pole configuration apply to a motor circuit?
The three-pole configuration serves the three phase conductors of a three-phase motor circuit. Plan the power connections around those three poles; a neutral connection is not applicable.
What should I account for when planning the conductor terminations?
The terminals are lugs, so plan for lug-terminated conductors. Use 14 AWG as the minimum wire size when selecting conductors for these terminations.
How should I use the temperature rating when planning an installation?
Use the -25C to 70C temperature rating when evaluating the installation environment. Account for temperature conditions at the device location, including heat within the enclosure.
What dimensions should I use to plan the mounting layout?
Use the 5.50 in height, 3.00 in width and 3.70 in depth to plan the mounting location. Arrange conductor routing so the rocker lever remains accessible.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.8 out of 5 based on 9 reviews.