Siemens 3VA6560-6JQ32-0AA0 Molded Case Circuit Breaker

  • 600A
  • 3 Pole
  • Unit Mount
Siemens 3VA6560-6JQ32-0AA0
Molded Case Circuit Breaker
Brand Siemens
SKU 3VA6560-6JQ32-0AA0
Select Item Condition
Earn 7272 SuperPoints
  • 600A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Siemens 3VA6560-6JQ32-0AA0 - 600A 3 Pole Molded Case Circuit Breaker

New

$7,272.97 In Stock

Quantity

Description

Built for circuit protection, the Siemens 3VA6560-6JQ32-0AA0 is a 3-pole molded case circuit breaker rated 600A and 600VAC. Its UL interrupting rating is 65kA at 480VAC. This breaker belongs to the 3VA6 series and uses an electronic trip. Its LSIG trip function provides long-time, short-time, instantaneous and ground-fault protection. The trip opens the circuit in response to overloads or faults.

Specifications

Key specifications
Brand Siemens
Part Number 3VA6560-6JQ32-0AA0
Series 3VA6
Amperage 600A
Poles 3
Mounting Style Unit Mount
Voltage 480VAC, 600VAC
Phase 3
AIC Rating 65kA @ 480VAC, 22kA @ 600VAC
Electrical ratings
Amperage Range 240-600A
Fit and installation
Frame Type 3VA65
Terminal Type Nut Keeper
Max Wire 600 kcmil
Min Wire 2/0 AWG
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LSIG
Trip Function Long-Time, Short-Time, Instantaneous, Ground Fault
Trip Adjustability Adjustable
Standards and features
Available Options Alarm Switch, Auxiliary Switch, Motor Operator, Shunt Trip, Undervoltage Release
Accessories Nut Keeper Kit
Standards IEC 60947-2, UL 489
Approval CE, CSA, UL
Temp Rating -25C to 70C
Construction Features HACR Rated, Reverse Feed

Product FAQs

7 answers
How do I choose a trip setting for the Siemens 3VA6560-6JQ32-0AA0?

The breaker has a 600A rated current and an adjustable trip range of 240-600A. Choose a setting within that range to suit the circuit's conductor ampacity and protection requirements.

How much available fault current can this breaker interrupt at 480VAC?

Its UL interrupting rating is 65kA at 480VAC. For a 480VAC installation, confirm that the available fault current at the installation point does not exceed 65kA.

How does the 600VAC rating guide circuit selection?

Select this breaker for circuits with an operating voltage no higher than its 600VAC rating. Voltage rating and interrupting rating serve different purposes, so also evaluate fault-clearing capacity at the circuit voltage.

What protection functions does the electronic LSIG trip offer?

LSIG means long-time, short-time, instantaneous and ground-fault protection. These electronic trip functions address overloads, short circuits and ground faults, helping guide protection coordination for the circuit.

What mounting style and physical space should I plan for?

This unit-mount breaker measures 12.5 in high, 8.3 in wide and 5.8 in deep. Use that footprint to plan the mounting location and allow working access for installation and conductor termination.

How are conductors terminated on this breaker?

The breaker uses screw-terminal connections. Proper conductor seating and screw tightening are important for maintaining a secure electrical connection during service.

What does the 3-pole construction mean during a trip?

The breaker opens all three poles together when it trips. This gives coordinated interruption of the three phase conductors.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

5.0
Rated 5.0 out of 5 stars
Based on 2 reviews
Rating
Ratings
2 reviews
  • PM
    Pete M.
    Verified Buyer
    Reviewing
    Siemens 3VA9243-0JB12 Lug kit
    I recommend this product
    Rated 5 out of 5 stars
    9/17/26
    Great price and avail

    Great price and showed up when I needed it.

  • RS
    Rochelle S.
    Verified Buyer
    Reviewing
    Siemens 3VA6225-5HL31-0AA0 - 250A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    10/2/25
    Smooth Transaction, Great Seller, Solid product

    I've ordered from SuperBreakers a couple times over the years. They have great customer service, knowledgeable employees, and I got my breaker in the expected timeline. I HIGHLY RECOMMEND this shop if you are a fellow circuit breaker enthusiast!

    Siemens makes a reliable product. Y'all already know.