Built for overcurrent protection, the Siemens 5SJ4210-8HG42 miniature circuit breaker has a 10A rating and two poles. Its interrupting rating is 14kA at 240VAC, with a single-phase configuration. This 5SJ4 series breaker uses a D trip curve. Copper is the conductor material, with a minimum wire size of 14 AWG and a maximum wire size of 4 AWG.
When should I select the Siemens 5SJ4210-8HG42 for a circuit?
Select this 10A miniature circuit breaker when the circuit requires 10A overcurrent protection. Coordinate that rating with the load requirements and conductor ampacity.
What does the 2-pole, single-phase arrangement mean for circuit selection?
The breaker provides a 2-pole arrangement for a single-phase circuit. Choose it when the circuit requires overcurrent protection on two conductors.
How do I apply the 14kA interrupting rating?
At 240VAC, the breaker has a 14kA interrupting rating. For that application, verify that the available fault current at the installation point does not exceed 14kA.
Why would I choose a D trip curve?
A D trip curve tolerates higher brief inrush currents before instantaneous tripping than more sensitive curves. Choose it when load startup current calls for that response, while coordinating fault protection with the circuit.
Can I adjust the thermal or magnetic trip settings?
Both the thermal and magnetic trip settings are fixed. The thermal element provides long-time overload protection, while the magnetic element provides instantaneous response to high fault current. Select the required rating and trip curve rather than planning to tune the breaker in the field.
What conductors can I terminate, and how are they secured?
Use copper conductors within the 14-4 AWG wire range. The screw-clamp terminals secure the conductors mechanically. Select conductor size within that range based on circuit ampacity and installation requirements.
How should I plan mounting space for this breaker?
The breaker supports surface or DIN rail mounting. Use its 4.92 in height, 3.3 in length and 1.57 in width when planning the physical layout and space for conductor routing.
Which voltage ratings should I check before selecting this breaker?
The voltage ratings are 240VAC, 480Y/277VAC and 125VDC. Select according to the circuit voltage and whether the system is AC or DC. For the 480Y/277VAC rating, use the wye system voltage arrangement when evaluating the application.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.