Siemens HFXD63B090 molded case circuit breaker is rated 90A with 3 poles, 3 phases and rated voltage of 600VAC, 500VDC. Interrupting rating is 65kAIC at 480V. The LI thermal magnetic trip has fixed thermal and adjustable magnetic settings. This SENTRON HFXD6 series breaker has an FD frame, panel mounting, a load side lug terminal connection and a width of 4.50 in.
HACR Rated, High Interrupting Capacity, Non-Interchangeable Trip, Reverse Feed
Product FAQs
7 answers
How should I use the 90A rating when selecting the Siemens HFXD63B090?
The 90A rated current is the starting point for coordinating the breaker with the circuit load and conductor protection requirements. Evaluate that current rating separately from the voltage and interrupting ratings.
What voltage ratings should I check for an AC or DC application?
The breaker is rated 600VAC and 500VDC. Select against the rating for your circuit's current type and voltage, and evaluate interrupting capacity separately.
Is this a three-pole breaker for a three-phase circuit?
This is a three-pole, three-phase molded case circuit breaker. Use the pole count and phase configuration when selecting protection for a three-phase circuit, alongside the current, voltage and interrupting ratings.
What protection does the thermal-magnetic LI trip provide?
The LI trip provides long-time and instantaneous overcurrent protection. Its thermal element responds to sustained overloads, while its magnetic element responds rapidly to high-current faults.
Which trip settings can I adjust?
The thermal trip is fixed, and the magnetic trip is adjustable. Adjustment applies to the magnetic pickup for high-current faults, so select that setting as part of the circuit's protection coordination.
How are the load conductors connected?
The load-side connection uses a lug. Plan the outgoing conductor termination around that connection method.
How does the 65kAIC at 480V rating affect selection?
At 480V, the available fault current at the installation point must not exceed the breaker's 65kAIC interrupting rating. Compare that rating with the available fault current when selecting the breaker.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.